Total scatter factor for small fields in radiotherapy: a dosimetric comparison

Total scatter factor for small fields in radiotherapy: a dosimetric comparison AbstractPurposeSmall field dosimetry is complicated and accuracy in the measurement of total scatter factor (TSF) is crucial for dosimetric calculations, in making optimum intensity-modulated radiotherapy plans for treating small target volumes. In this study, we intended to determine the TSF measuring properties of CC01 and CC04 detectors for field sizes ranging from sub-centimetre to the centimetre fields.Material and methodsCC01 and CC04 chamber detectors were used to measure TSF for 6 and 18 MV photon beam delivered from the linear accelerator, through small fields in a water phantom. Small fields were created by collimator jaws and multi-leaf collimators separately, with field sizes ranging from 0·6 to 10 cm2 and 0·5 to 20 cm2, respectively.ResultsCC01 measured TSF at all the given field sizes created by jaws and multi-leaf collimators for both 6 and 18 MV beams whereas CC04 could not measure TSF for field sizes <1 cm2 due to volume averaging and perturbation effects.ConclusionCC01 was shown to be effective for measurement of TSF in sub-centimetre field sizes. CC01 can be employed to measure other dosimetric quantities in small fields using different energy beams. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Radiotherapy in Practice Cambridge University Press

Total scatter factor for small fields in radiotherapy: a dosimetric comparison

Journal of Radiotherapy in Practice , Volume 17 (3): 5 – Nov 27, 2017

Loading next page...
 
/lp/cambridge-university-press/total-scatter-factor-for-small-fields-in-radiotherapy-a-dosimetric-64cnFZNhpQ

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Cambridge University Press
Copyright
© Cambridge University Press 2017 
ISSN
1467-1131
eISSN
1460-3969
DOI
10.1017/S1460396917000681
Publisher site
See Article on Publisher Site

Abstract

AbstractPurposeSmall field dosimetry is complicated and accuracy in the measurement of total scatter factor (TSF) is crucial for dosimetric calculations, in making optimum intensity-modulated radiotherapy plans for treating small target volumes. In this study, we intended to determine the TSF measuring properties of CC01 and CC04 detectors for field sizes ranging from sub-centimetre to the centimetre fields.Material and methodsCC01 and CC04 chamber detectors were used to measure TSF for 6 and 18 MV photon beam delivered from the linear accelerator, through small fields in a water phantom. Small fields were created by collimator jaws and multi-leaf collimators separately, with field sizes ranging from 0·6 to 10 cm2 and 0·5 to 20 cm2, respectively.ResultsCC01 measured TSF at all the given field sizes created by jaws and multi-leaf collimators for both 6 and 18 MV beams whereas CC04 could not measure TSF for field sizes <1 cm2 due to volume averaging and perturbation effects.ConclusionCC01 was shown to be effective for measurement of TSF in sub-centimetre field sizes. CC01 can be employed to measure other dosimetric quantities in small fields using different energy beams.

Journal

Journal of Radiotherapy in PracticeCambridge University Press

Published: Nov 27, 2017

Keywords: chamber detectors CC01 and CC04; collimator jaws; linear accelerator; multi-leaf collimators; small field dosimetry