Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Influence of river floods on the humification process in the bottom sediments from the Goczałkowice reservoir

Influence of river floods on the humification process in the bottom sediments from the... The paper presents the results of studies on the influence of the 2010 Vistula flood on the humification process in the bottom sediments of the Goczalkowice Reservoir in southern Poland. Due to its location in the vicinity of farmlands, forests and urbanized areas, the Goczalkowice Reservoir is characterized by amplified and intense humification processes within its sediments. The studies were focused on the determining the influence of the flood wave containing organic and inorganic suspensions on these processes. Humic acids were analyzed using two spectroscopic methods: Electron Paramagnetic Resonance (EPR) and Fourier Transform Infrared Spectroscopy (FT-IR). Application of these methods allowed to determine the values of free radicals and of the g-factor, which are indicators of oxidation, aromatization and maturation of humic acids during the humification process, as well as the value of the 1650/1720 ratio, reflecting the dissociation of the COOH group to COO- and the formation of complexes of transitional metals with humic acids during the humification process. Introduction The influence of floods on the functioning of valley-dammed reservoir ecosystems has not been sufficiently studied yet. Flooding may cause rapid, sometimes irrevocable changes in environmental parameters such as water velocity, content of oxygen dissolved in water, amount of water-suspended matter (Fenske et al. 2001, Lenzia et al. 2000, Tesi et al. 2013, Ibragimov et al. 2010)), or the quality of phyto- and zooplankton in particular parts of the reservoir. It is estimated that the flood wave causes the inflow of large amounts of dissolved compounds (mainly nitrates and phosphates) resulting from algal blooms and the appearance of cyanobacteria in the shallower parts of the reservoir (Godlewska et al. 2003). The flood wave generates also the transport of alluvial or lacustrine material from the bottom of the channel or water reservoir, thus causing changes in the amount and quality of humic acids (Lenzia et al. 2000, Milligan et al. 2007, Tesi et al. 2013). Intense flow of water to rivers and lakes results in the introduction of farming, communal and industrial pollution (Martinez-Santos et al. 2015). Considerable inflow of organic matter with the flood wave causes changes in the humification processes within the sediments, and thus alterations in the physical and chemical properties of the studied humic acids (Fenske et al. 2001, Godlewska et al. 2003). This paper is focused on the study of the influence of the Vistula flood on the humification processes in the bottom sediments of the Goczalkowice Reservoir. Object and methods of study The Goczalkowice Reservoir (49°51' N, 18°52'E) was constructed in the 1950s on the 67th km of the Vistula River as a reservoir for potable and industrial water for the Upper Silesian Industrial Region as well as a reduction of the flood wave that could develop on the Vistula River. The total volume of the reservoir at maximal backwater is 165.6 hm3 and its area is 32 km2. Its maximal length is 12 km and width ­ 5 km. In the summer season (June­August) the flood reserve is at the level of 45 hm3 and in the remaining months ­ at 38 hm3 (Siudy et al. 2005, Szostak et al. 2005). During the 2010 flood, three flood waves were noted on the Vistula River. The first two waves reached the Goczalkowice Reservoir on the 17th and 19th May 2010, and the third ­ on the 2nd and 3rd June. During the first flood wave, the inflow was at the level of 544 m3/s, and during the second wave ­ at 408 m3/s, which was linked with intense rainfall in Brenna that occurred between 15th and 19th May. The third flood wave, with an inflow of 200 m3/s, resulted from intense rainfall in Brenna between 28th May and 3rd June [personal data ­ GPW Katowice]. The evaluation was based on selected physical and chemical indicators of humic acids extracted from the bottom sediments. Samples for studies were collected by workers of the (GPW) according to Polish standards [PN-ISO 5667-15:2004]. The material was collected in four parts of the Goczalkowice Reservoir prior to and after the 2010 flood: prior to the flood on 4th June 2009 (spring 2009) and 28th August 2009 (summer 2009), as well as after the flood on 21st June 2010 (spring 2010) (Fig. 1; Table 1). Sample number 1 was collected in the area of Vistula channel, 3,6 km upstream the dam. Sample number 2 and 3 were collected in south part of the reservoir in littoral zone. Sample number 4 was collected in the deepest zone of the reservoir Goczalkowice. Humic substances were extracted from the samples of bottom sediments from the Goczalkowice Reservoir using the alkaline extraction method according to IHSS (International Humic Substances Society) procedure. (2.31 × 1017 [spin/g]), and the g-factor was compared to the strong pitch benchmark (g = 2.0028). The infrared spectra were obtained with a FT-IR spectrometer Spektrum One PERKIN ELMER. The samples were prepared as pellets with KBr. The obtained spectra were analyzed using AISN Software Inc. Peak FitTM software version 4, determining the 1650/1720 ratio. The 1650/1720 ratio was calculated by subdividing the area below the Gauss curve with the maximum at 1650 by the area below the Gauss curve with the maximum at 1720. Results and discussion Based on EPR spectra for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir, the values of the g-factor and free radical concentration have been determined (Fig. 2; Table 2). The obtained values of the g-factor are in the range of 2.0026 to 2.0031; they are typical of humic acids extracted from bottom sediments from other water reservoirs and comparable with the values of the g-factor obtained for compost (2.0031­2.0034) and sewage sludge (2.0028­2.0034) (Polak et al. 2011, Polak et al. 2009). The free radical concentrations were lower than the values obtained for humic acids extracted from soils (3 × 1017 to 24 × 1017 [spin/g]) (Watanable et al. 2005) and similar to the free radical concentration of humic acids extracted from compost, bottom sediments and sewage sludge (0.19 × 1017 [spin/g] ­ 5.1 × 1017 [spin/g]) (Polak et al. 2009). The mean values of the g-factor for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir prior to and after the 2010 flood lie within the standard error, whereas the mean values of free radical concentrations for humic acids extracted prior to and after the 2010 flood reflect a significant decrease (Fig. 2 and 3; Table 2). Thus, it may be assumed that changes caused by the flood wave did not influence the value of the g-factor for humic substances extracted from the bottom sediments. Most probably, passing of the flood wave caused a simultaneous increase of the intensity of oxidation processes, enrichment of humic substances in oxygen-containing functional groups (increase of g-factor), [personal elaboration, source: maps.geoportal.gov.pl] Fig. 1. Sampling sites of sediments in the Goczalkowice Reservoir Table 1. Measurement and inspection points in the Goczalkowice Reservoir Sampling site (no. of sample) 1 2 3 4 Depth 5m 1.5 m 1m 11 m Geographic longitude 18° 53' 12'' E 18° 50' 09'' E 18° 49' 19" E 18° 54'49" E Geographic latitude 49° 56' 02'' N 49° 55' 17'' N 49° 55' 26" N 49° 56' 33" N Measurement and inspection point Central part of the Reservoir Shallow 100 Reservoir backflow "Goczalkowice" uptake containing elevated amounts of organic matter, biogenic substances and soil fractions from the drainage basin (Fenske et al. 2001, Mazurkiewicz et al. 1998, Tesi et al. 2013, Ibragimov et al. 2010). Rapid water flow may cause increase of water turbidity, which in consequence leads to changes in the distribution and functioning of zoobenthos in the bottom sediments of the reservoir, a fact that was noted in the case of a flood that passed through the Dobczyce Reservoir in southern Poland (Godlewska et al. 2003). as well as aromatization processes (decrease of g-factor) (Polak et al. 2011, Polak et al. 2007). In turn, the observed decrease of the mean values of free radical concentrations may suggest: a low content of oxygen-containing functional groups, low maturity of humic acids and a larger number of aromatic structures in the studied humic acids. The variability of the free radical concentrations, similarly as in the case of the Odra flood, may be linked with the change of intensity of microbiological processes with the inflow of flood water Table 2. Values of the g-factor and the free radical concentration for humic acids extracted from sediments of the Goczalkowice Reservoir prior to and after the 2010 flood g-factor Prior to the flood Sampling site (no. of sample) 1 2 3 4 Spring 2009 2.00330 ± 0.00006 2.00300 ± 0.00020 2.00330 ± 0.00015 2.00340 ± 0.00010 2.00325 ± 0.00017 Summer 2009 2.00330 ± 0.00005 2.00330 ± 0.00010 2.00330 ± 0.00010 2.00330 ± 0.00010 2.00330 ± 0.00009 After the flood Spring 2010 2.00345 ± 0.00001 2.00325 ± 0.00007 2.00316 ± 0.00014 2.00339 ± 0.00008 2.00331 ± 0.00013 2.00331 ± 0.00013 Free radical concentration Prior to the flood [spin/g] Spring 2009 7.74 ± 0.02 ×1016 11.50 ± 0.50 × 1016 6.62 ± 0.53 × 1016 10.80 ± 0.02 × 1016 Summer 2009 8.89 ± 1.10 × 1016 3.69 ± 0.65 × 1016 5.65 ± 1.08 × 1016 4.45 ± 0.10 × 1016 After the flood [spin/g] Spring 2010 3.37 ± 1.39 ×1016 1.48 ± 0.86 × 1016 2.56 ± 0.21 × 1016 2.73 ± 0.87 × 1016 Mean ± SD Mean prior to and after the 2010 flood ± SD 9.17 ± 2.35 × 1016 5.67 ± 2.29 × 1016 2.54 ± 0.79 × 1016 2.00328 ± 0.00012 7.42 ± 2.85 × 1016 2.54 ± 0.79 × 1016 Fig. 2. Values of the g-factor for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir prior to and after the 2010 flood Fig. 3. Values of free radical concentrations for humic acids extracted from sediments of the Goczalkowice Reservoir prior to and after the 2010 flood Comparison of the determined values of the g-factor for humic acids extracted from the bottom sediments from various parts of the Goczalkowice Reservoir prior to and after the 2010 flood has indicated its slight increase for humic acids extracted from the bottom sediments collected in site 1 (from 2.00330 to 2.00345) (Fig. 2; Table 2). The observed increase of the g-factor may point to the elevated content of the oxygen-containing functional groups in the extracted humic acids (Polak et al. 2009, Polak et al. 2007) and may indicate the intensification of oxygen processes at the expense of aromatization processes in this part of the reservoir (Polak et al. 2011). However, the concentrations of free radicals obtained for this sample indicate a decrease, which in turn points to the limitation of the oxygen processes and inhibition of humification. Due to rapid influx of organic matter e.g. from the flooded areas around the reservoir, the flood wave containing more oxygenated humic acids probably disturbed the upper layer of the bottom sediments, causing deepening of the reservoir and influencing their stability (CzaplickaKotas et al. 2004). The low values of the g-factor and the free radical concentration for humic acids extracted from the bottom sediments collected in site 3 after the 2010 flood (Fig. 2 and 3; Table 2) may indicate lower maturity of the humic acids and higher content of the aromatic structures within them (Polak et al. 2011, Polak et al. 2007). It seems that increase of humic acids aromatization causes the dislocation of the unpaired electrons of semiquinone radicals between the oxygen atom and aromatic carbon atoms, which in consequence leads to the decrease of the g-factor (Polak et al. 2009). Decrease of the g-factor for humic acids may be caused by the formation of transition metal complexes or the occurrence of these metals in humic acids transported with the flood wave (Ibragimov et al. 2010). It has been evidenced that the presence of lead and mercury complexes may result in the decrease of the g-factor in comparison to values typical of semiquinone radicals i.e. 2.0034 to 1.9999 (Polak et al. 2005). On the other hand, it should be noted that the bottom sediments have different ability to accumulate pollutants from water due to their large sorption capacity and grained size (Martinez-Santos et al. 2015). Fine-grained silt and sediments (silt and clay fraction) have the ability to accumulate greater amounts of pollutants than coarse particles. Clay minerals and organic matter contain higher levels of heavy metals than sandy sediments. (Arifur Rahman et al. 2010, Polak et al. 2007, Fenske et al. 2001, Tesi et al. 2013, Mlynarczyk et al. 2013). The analyses of grain size and concentration of heavy metals in bottom sediments were not performed at this stage of research. The lowest free radical concentration and at the same time its largest decrease in comparison to values prior to the flood have been observed for the sample collected in site 2 (1.48 ± 0.86 × 1016 [spin/g]). This locality is one of the shallowest within the Goczalkowice Reservoir (1.5 m), situated near to a peatland reservation to the east from the Zarzecze pump station up to the mouth of the Bajerka stream (Czaplicka-Kotas et al. 2010, Szaliska et al. 2010). Surface waters supplied by groundwater and intense rainfall flow through the marshy peatland contain increased amounts of manganese and iron and cause destabilization of the free radicals content (Czaplicka-Kotas et al. 2010, Czaplicka-Kotas et al. 2004, Polak et al. 2009, Mlynarczyk et al. 2013). Based on the variability of the free radical concentration and values of the g-factor determined from EPR spectra for humic acids extracted from the sediments of the Goczalkowice Reservoir, it can be assumed that the determined free radical concentrations most probably better reflect the changing conditions in the reservoir after the flood because they register a significant decrease. The value of the g-factor practically does not undergo any changes, which may be the consequence of multiple processes. Connection of metals with phenol groups in the humic acids causes shift of the quinon hydroquinon equilibrium towards the hydroquinone groups, which results in the decrease of the free radical concentration (Polak et al. 2011). Analysis of FT-IR spectra for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir prior to and after the 2010 flood confirms the presence of characteristic functional groups. The most crucial information, obtained the formation of transition metal complexes in the structure of the analyzed humic acids (Table 3; Fig. 5) (Giovela et al. 2004, Polak et al. 2005). The results of these analyses confirm the suggested influence of metals in samples of the extracted humic acids. Moreover, the results are in concordance with the results of the g-factor and free radicals analysis. Passing of the flood wave has resulted in enhanced influx of metals to the bottom sediments and subsequent formation of metal complexes. Content of transition metals in the flood wave have resulted from the water flow through farming soils containing cadmium and lead and through the area of the peatland reservation, which contains large amounts of iron and manganese (Siudy et al. 2005, Szaliska et al. 2010, Ibragimov et al. 2010). In other reservoirs (Szczecin Lagoon, Dobczyce Reservoir) and rivers (Severn, Po), increased amounts of transition metals were also noted in the bottom sediments after passing of the flood wave, pointing to the inflow of polluted water from areas surrounding the studied rivers and reservoirs (Czaplicka-Kotas et al. 2010, Fenske et al. 2001, Fooken et al. 2003, Zhaoa et al. 1999, from the FT-IR spectral analysis, is enhancement of the intensity of the band COO- = 1650 cm-1 typical of the COOgroup and disappearance of the band typical of non-dissociated carboxylic groups at C=O = 1720 cm-1, which may indicate dissociation of the COOH group to COO- (Fooken et al. 2003) and the formation of transition metal complexes with humic acids during the humification process (Arifur Rahman et al. 2010, Polak et al. 2007). The values of the 1650/1720 ratio for humic acids extracted from the bottom sediments collected in four localities in the Goczalkowice Reservoir prior to and after the flood indicate that after the flood, the ratio for humic acids collected in sites 2, 3 and 4 increases, whereas an insignificant decrease is observed in the case of humic acids collected in site 1, during the observation the values g-factor increase. It is not obvious to explain why the values of the 1650/1720 ratio and g-factor are so different, most probably this is caused by the complexity of physical and chemical processes occurring during the passage of the flood wave. This fact of 1650/1720 ratio decrease may be explained as the dissociation of the COOH group to COO- and Fig. 4. Distribution of the FT-IR spectra for the humic acid extracted from the sediment collected in sampling site 1 after the flood on the Goczalkowice Reservoir on particular Gaussian amplitudes Table 3. Values of area (%) and 1650/1720 ratio for humic acids extracted from the sediments of the Goczalkowice Reservoir prior to and after the 2010 flood Absorption band Sampling site (no. of sample) COO- = 1650 cm-1 Prior to the flood Spring 2009 2.03337 2.91922 2.52106 1.21354 Summer 2009 2.40168 2.68572 2.16262 2.03240 After the flood Spring 2010 4.34554 1.74152 2.25364 1.71441 C=O = 1720 cm-1 Prior to the flood Spring 2009 1.19350 2.23311 1.71104 0.67861 Summer 2009 1.53070 2.39907 1.68589 1.58360 After the flood Spring 2010 2.82661 1.27490 0.87400 0.96609 1650/1720 ratio After the flood Spring 2010 1.53736 1.36601 2.57855 1.77458 Prior to the flood Spring 2009 1.70356 1.30725 1.47340 1.78830 Summer 2009 1.56901 1.11949 1.28277 1.28341 Fig. 5. Values of the 1650/1720 ratio for humic acids extracted from the sediments of the Goczalkowice Ibragimov et al. 2010). The interaction of heavy metals with humic acids and the effect of particle size on the ability of their accumulation during the passage of the flood wave need further study. The Institute of Environmental Protection, together with its collaborating institutions plan to conduct further research on the processes occurring during the floods. Acknowledgements The paper was based on the results of the study conducted in the Department of Material Chemistry and Chemical Technology, University of Silesia, under the supervision of Dr. Justyna Polak, to whom we are very grateful. Summary and conclusions It is not clear exactly which physical and chemical processes took place during passing of the flood wave formed on the Vistula River by the Goczalkowice Reservoir, because these are very complex and very dynamic processes, requiring multiannual studies. The conducted spectroscopic analyses of the humic acids extracted from the bottom sediments collected in the Goczalkowice Reservoir prior to and after the flood allow for the following conclusions: 1. Decrease of the free radical concentrations, changes in the values of the g-factor and the 1650/1720 ratio observed after passing of the flood wave indicate the formation of transition metal complexes with humic acids or the occurrence of these metals in the structure of humic acids transported with the flood waters from the flooded area around the Goczalkowice Reservoir. 2. It seems that the variability of organic matter indicators in the Goczalkowice Reservoir after the flood is best reflected by the changes of the free radical concentration, which points to the lower maturity of humic acids from the bottom sediments. This would indicate hampering or rather disturbance of the process with passing of the flood wave. 3. Lack of differences or low variability in the values of the remaining parameters after the flood may result from the simultaneous processes of oxidation and aromatization, which is evidenced by the mutually excluding values of g-factor and free radical concentration. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Environmental Protection de Gruyter

Influence of river floods on the humification process in the bottom sediments from the Goczałkowice reservoir

Loading next page...
 
/lp/de-gruyter/influence-of-river-floods-on-the-humification-process-in-the-bottom-OiiG8ZUJYK
Publisher
de Gruyter
Copyright
Copyright © 2016 by the
ISSN
2083-4810
eISSN
2083-4810
DOI
10.1515/aep-2016-0017
Publisher site
See Article on Publisher Site

Abstract

The paper presents the results of studies on the influence of the 2010 Vistula flood on the humification process in the bottom sediments of the Goczalkowice Reservoir in southern Poland. Due to its location in the vicinity of farmlands, forests and urbanized areas, the Goczalkowice Reservoir is characterized by amplified and intense humification processes within its sediments. The studies were focused on the determining the influence of the flood wave containing organic and inorganic suspensions on these processes. Humic acids were analyzed using two spectroscopic methods: Electron Paramagnetic Resonance (EPR) and Fourier Transform Infrared Spectroscopy (FT-IR). Application of these methods allowed to determine the values of free radicals and of the g-factor, which are indicators of oxidation, aromatization and maturation of humic acids during the humification process, as well as the value of the 1650/1720 ratio, reflecting the dissociation of the COOH group to COO- and the formation of complexes of transitional metals with humic acids during the humification process. Introduction The influence of floods on the functioning of valley-dammed reservoir ecosystems has not been sufficiently studied yet. Flooding may cause rapid, sometimes irrevocable changes in environmental parameters such as water velocity, content of oxygen dissolved in water, amount of water-suspended matter (Fenske et al. 2001, Lenzia et al. 2000, Tesi et al. 2013, Ibragimov et al. 2010)), or the quality of phyto- and zooplankton in particular parts of the reservoir. It is estimated that the flood wave causes the inflow of large amounts of dissolved compounds (mainly nitrates and phosphates) resulting from algal blooms and the appearance of cyanobacteria in the shallower parts of the reservoir (Godlewska et al. 2003). The flood wave generates also the transport of alluvial or lacustrine material from the bottom of the channel or water reservoir, thus causing changes in the amount and quality of humic acids (Lenzia et al. 2000, Milligan et al. 2007, Tesi et al. 2013). Intense flow of water to rivers and lakes results in the introduction of farming, communal and industrial pollution (Martinez-Santos et al. 2015). Considerable inflow of organic matter with the flood wave causes changes in the humification processes within the sediments, and thus alterations in the physical and chemical properties of the studied humic acids (Fenske et al. 2001, Godlewska et al. 2003). This paper is focused on the study of the influence of the Vistula flood on the humification processes in the bottom sediments of the Goczalkowice Reservoir. Object and methods of study The Goczalkowice Reservoir (49°51' N, 18°52'E) was constructed in the 1950s on the 67th km of the Vistula River as a reservoir for potable and industrial water for the Upper Silesian Industrial Region as well as a reduction of the flood wave that could develop on the Vistula River. The total volume of the reservoir at maximal backwater is 165.6 hm3 and its area is 32 km2. Its maximal length is 12 km and width ­ 5 km. In the summer season (June­August) the flood reserve is at the level of 45 hm3 and in the remaining months ­ at 38 hm3 (Siudy et al. 2005, Szostak et al. 2005). During the 2010 flood, three flood waves were noted on the Vistula River. The first two waves reached the Goczalkowice Reservoir on the 17th and 19th May 2010, and the third ­ on the 2nd and 3rd June. During the first flood wave, the inflow was at the level of 544 m3/s, and during the second wave ­ at 408 m3/s, which was linked with intense rainfall in Brenna that occurred between 15th and 19th May. The third flood wave, with an inflow of 200 m3/s, resulted from intense rainfall in Brenna between 28th May and 3rd June [personal data ­ GPW Katowice]. The evaluation was based on selected physical and chemical indicators of humic acids extracted from the bottom sediments. Samples for studies were collected by workers of the (GPW) according to Polish standards [PN-ISO 5667-15:2004]. The material was collected in four parts of the Goczalkowice Reservoir prior to and after the 2010 flood: prior to the flood on 4th June 2009 (spring 2009) and 28th August 2009 (summer 2009), as well as after the flood on 21st June 2010 (spring 2010) (Fig. 1; Table 1). Sample number 1 was collected in the area of Vistula channel, 3,6 km upstream the dam. Sample number 2 and 3 were collected in south part of the reservoir in littoral zone. Sample number 4 was collected in the deepest zone of the reservoir Goczalkowice. Humic substances were extracted from the samples of bottom sediments from the Goczalkowice Reservoir using the alkaline extraction method according to IHSS (International Humic Substances Society) procedure. (2.31 × 1017 [spin/g]), and the g-factor was compared to the strong pitch benchmark (g = 2.0028). The infrared spectra were obtained with a FT-IR spectrometer Spektrum One PERKIN ELMER. The samples were prepared as pellets with KBr. The obtained spectra were analyzed using AISN Software Inc. Peak FitTM software version 4, determining the 1650/1720 ratio. The 1650/1720 ratio was calculated by subdividing the area below the Gauss curve with the maximum at 1650 by the area below the Gauss curve with the maximum at 1720. Results and discussion Based on EPR spectra for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir, the values of the g-factor and free radical concentration have been determined (Fig. 2; Table 2). The obtained values of the g-factor are in the range of 2.0026 to 2.0031; they are typical of humic acids extracted from bottom sediments from other water reservoirs and comparable with the values of the g-factor obtained for compost (2.0031­2.0034) and sewage sludge (2.0028­2.0034) (Polak et al. 2011, Polak et al. 2009). The free radical concentrations were lower than the values obtained for humic acids extracted from soils (3 × 1017 to 24 × 1017 [spin/g]) (Watanable et al. 2005) and similar to the free radical concentration of humic acids extracted from compost, bottom sediments and sewage sludge (0.19 × 1017 [spin/g] ­ 5.1 × 1017 [spin/g]) (Polak et al. 2009). The mean values of the g-factor for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir prior to and after the 2010 flood lie within the standard error, whereas the mean values of free radical concentrations for humic acids extracted prior to and after the 2010 flood reflect a significant decrease (Fig. 2 and 3; Table 2). Thus, it may be assumed that changes caused by the flood wave did not influence the value of the g-factor for humic substances extracted from the bottom sediments. Most probably, passing of the flood wave caused a simultaneous increase of the intensity of oxidation processes, enrichment of humic substances in oxygen-containing functional groups (increase of g-factor), [personal elaboration, source: maps.geoportal.gov.pl] Fig. 1. Sampling sites of sediments in the Goczalkowice Reservoir Table 1. Measurement and inspection points in the Goczalkowice Reservoir Sampling site (no. of sample) 1 2 3 4 Depth 5m 1.5 m 1m 11 m Geographic longitude 18° 53' 12'' E 18° 50' 09'' E 18° 49' 19" E 18° 54'49" E Geographic latitude 49° 56' 02'' N 49° 55' 17'' N 49° 55' 26" N 49° 56' 33" N Measurement and inspection point Central part of the Reservoir Shallow 100 Reservoir backflow "Goczalkowice" uptake containing elevated amounts of organic matter, biogenic substances and soil fractions from the drainage basin (Fenske et al. 2001, Mazurkiewicz et al. 1998, Tesi et al. 2013, Ibragimov et al. 2010). Rapid water flow may cause increase of water turbidity, which in consequence leads to changes in the distribution and functioning of zoobenthos in the bottom sediments of the reservoir, a fact that was noted in the case of a flood that passed through the Dobczyce Reservoir in southern Poland (Godlewska et al. 2003). as well as aromatization processes (decrease of g-factor) (Polak et al. 2011, Polak et al. 2007). In turn, the observed decrease of the mean values of free radical concentrations may suggest: a low content of oxygen-containing functional groups, low maturity of humic acids and a larger number of aromatic structures in the studied humic acids. The variability of the free radical concentrations, similarly as in the case of the Odra flood, may be linked with the change of intensity of microbiological processes with the inflow of flood water Table 2. Values of the g-factor and the free radical concentration for humic acids extracted from sediments of the Goczalkowice Reservoir prior to and after the 2010 flood g-factor Prior to the flood Sampling site (no. of sample) 1 2 3 4 Spring 2009 2.00330 ± 0.00006 2.00300 ± 0.00020 2.00330 ± 0.00015 2.00340 ± 0.00010 2.00325 ± 0.00017 Summer 2009 2.00330 ± 0.00005 2.00330 ± 0.00010 2.00330 ± 0.00010 2.00330 ± 0.00010 2.00330 ± 0.00009 After the flood Spring 2010 2.00345 ± 0.00001 2.00325 ± 0.00007 2.00316 ± 0.00014 2.00339 ± 0.00008 2.00331 ± 0.00013 2.00331 ± 0.00013 Free radical concentration Prior to the flood [spin/g] Spring 2009 7.74 ± 0.02 ×1016 11.50 ± 0.50 × 1016 6.62 ± 0.53 × 1016 10.80 ± 0.02 × 1016 Summer 2009 8.89 ± 1.10 × 1016 3.69 ± 0.65 × 1016 5.65 ± 1.08 × 1016 4.45 ± 0.10 × 1016 After the flood [spin/g] Spring 2010 3.37 ± 1.39 ×1016 1.48 ± 0.86 × 1016 2.56 ± 0.21 × 1016 2.73 ± 0.87 × 1016 Mean ± SD Mean prior to and after the 2010 flood ± SD 9.17 ± 2.35 × 1016 5.67 ± 2.29 × 1016 2.54 ± 0.79 × 1016 2.00328 ± 0.00012 7.42 ± 2.85 × 1016 2.54 ± 0.79 × 1016 Fig. 2. Values of the g-factor for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir prior to and after the 2010 flood Fig. 3. Values of free radical concentrations for humic acids extracted from sediments of the Goczalkowice Reservoir prior to and after the 2010 flood Comparison of the determined values of the g-factor for humic acids extracted from the bottom sediments from various parts of the Goczalkowice Reservoir prior to and after the 2010 flood has indicated its slight increase for humic acids extracted from the bottom sediments collected in site 1 (from 2.00330 to 2.00345) (Fig. 2; Table 2). The observed increase of the g-factor may point to the elevated content of the oxygen-containing functional groups in the extracted humic acids (Polak et al. 2009, Polak et al. 2007) and may indicate the intensification of oxygen processes at the expense of aromatization processes in this part of the reservoir (Polak et al. 2011). However, the concentrations of free radicals obtained for this sample indicate a decrease, which in turn points to the limitation of the oxygen processes and inhibition of humification. Due to rapid influx of organic matter e.g. from the flooded areas around the reservoir, the flood wave containing more oxygenated humic acids probably disturbed the upper layer of the bottom sediments, causing deepening of the reservoir and influencing their stability (CzaplickaKotas et al. 2004). The low values of the g-factor and the free radical concentration for humic acids extracted from the bottom sediments collected in site 3 after the 2010 flood (Fig. 2 and 3; Table 2) may indicate lower maturity of the humic acids and higher content of the aromatic structures within them (Polak et al. 2011, Polak et al. 2007). It seems that increase of humic acids aromatization causes the dislocation of the unpaired electrons of semiquinone radicals between the oxygen atom and aromatic carbon atoms, which in consequence leads to the decrease of the g-factor (Polak et al. 2009). Decrease of the g-factor for humic acids may be caused by the formation of transition metal complexes or the occurrence of these metals in humic acids transported with the flood wave (Ibragimov et al. 2010). It has been evidenced that the presence of lead and mercury complexes may result in the decrease of the g-factor in comparison to values typical of semiquinone radicals i.e. 2.0034 to 1.9999 (Polak et al. 2005). On the other hand, it should be noted that the bottom sediments have different ability to accumulate pollutants from water due to their large sorption capacity and grained size (Martinez-Santos et al. 2015). Fine-grained silt and sediments (silt and clay fraction) have the ability to accumulate greater amounts of pollutants than coarse particles. Clay minerals and organic matter contain higher levels of heavy metals than sandy sediments. (Arifur Rahman et al. 2010, Polak et al. 2007, Fenske et al. 2001, Tesi et al. 2013, Mlynarczyk et al. 2013). The analyses of grain size and concentration of heavy metals in bottom sediments were not performed at this stage of research. The lowest free radical concentration and at the same time its largest decrease in comparison to values prior to the flood have been observed for the sample collected in site 2 (1.48 ± 0.86 × 1016 [spin/g]). This locality is one of the shallowest within the Goczalkowice Reservoir (1.5 m), situated near to a peatland reservation to the east from the Zarzecze pump station up to the mouth of the Bajerka stream (Czaplicka-Kotas et al. 2010, Szaliska et al. 2010). Surface waters supplied by groundwater and intense rainfall flow through the marshy peatland contain increased amounts of manganese and iron and cause destabilization of the free radicals content (Czaplicka-Kotas et al. 2010, Czaplicka-Kotas et al. 2004, Polak et al. 2009, Mlynarczyk et al. 2013). Based on the variability of the free radical concentration and values of the g-factor determined from EPR spectra for humic acids extracted from the sediments of the Goczalkowice Reservoir, it can be assumed that the determined free radical concentrations most probably better reflect the changing conditions in the reservoir after the flood because they register a significant decrease. The value of the g-factor practically does not undergo any changes, which may be the consequence of multiple processes. Connection of metals with phenol groups in the humic acids causes shift of the quinon hydroquinon equilibrium towards the hydroquinone groups, which results in the decrease of the free radical concentration (Polak et al. 2011). Analysis of FT-IR spectra for humic acids extracted from the bottom sediments of the Goczalkowice Reservoir prior to and after the 2010 flood confirms the presence of characteristic functional groups. The most crucial information, obtained the formation of transition metal complexes in the structure of the analyzed humic acids (Table 3; Fig. 5) (Giovela et al. 2004, Polak et al. 2005). The results of these analyses confirm the suggested influence of metals in samples of the extracted humic acids. Moreover, the results are in concordance with the results of the g-factor and free radicals analysis. Passing of the flood wave has resulted in enhanced influx of metals to the bottom sediments and subsequent formation of metal complexes. Content of transition metals in the flood wave have resulted from the water flow through farming soils containing cadmium and lead and through the area of the peatland reservation, which contains large amounts of iron and manganese (Siudy et al. 2005, Szaliska et al. 2010, Ibragimov et al. 2010). In other reservoirs (Szczecin Lagoon, Dobczyce Reservoir) and rivers (Severn, Po), increased amounts of transition metals were also noted in the bottom sediments after passing of the flood wave, pointing to the inflow of polluted water from areas surrounding the studied rivers and reservoirs (Czaplicka-Kotas et al. 2010, Fenske et al. 2001, Fooken et al. 2003, Zhaoa et al. 1999, from the FT-IR spectral analysis, is enhancement of the intensity of the band COO- = 1650 cm-1 typical of the COOgroup and disappearance of the band typical of non-dissociated carboxylic groups at C=O = 1720 cm-1, which may indicate dissociation of the COOH group to COO- (Fooken et al. 2003) and the formation of transition metal complexes with humic acids during the humification process (Arifur Rahman et al. 2010, Polak et al. 2007). The values of the 1650/1720 ratio for humic acids extracted from the bottom sediments collected in four localities in the Goczalkowice Reservoir prior to and after the flood indicate that after the flood, the ratio for humic acids collected in sites 2, 3 and 4 increases, whereas an insignificant decrease is observed in the case of humic acids collected in site 1, during the observation the values g-factor increase. It is not obvious to explain why the values of the 1650/1720 ratio and g-factor are so different, most probably this is caused by the complexity of physical and chemical processes occurring during the passage of the flood wave. This fact of 1650/1720 ratio decrease may be explained as the dissociation of the COOH group to COO- and Fig. 4. Distribution of the FT-IR spectra for the humic acid extracted from the sediment collected in sampling site 1 after the flood on the Goczalkowice Reservoir on particular Gaussian amplitudes Table 3. Values of area (%) and 1650/1720 ratio for humic acids extracted from the sediments of the Goczalkowice Reservoir prior to and after the 2010 flood Absorption band Sampling site (no. of sample) COO- = 1650 cm-1 Prior to the flood Spring 2009 2.03337 2.91922 2.52106 1.21354 Summer 2009 2.40168 2.68572 2.16262 2.03240 After the flood Spring 2010 4.34554 1.74152 2.25364 1.71441 C=O = 1720 cm-1 Prior to the flood Spring 2009 1.19350 2.23311 1.71104 0.67861 Summer 2009 1.53070 2.39907 1.68589 1.58360 After the flood Spring 2010 2.82661 1.27490 0.87400 0.96609 1650/1720 ratio After the flood Spring 2010 1.53736 1.36601 2.57855 1.77458 Prior to the flood Spring 2009 1.70356 1.30725 1.47340 1.78830 Summer 2009 1.56901 1.11949 1.28277 1.28341 Fig. 5. Values of the 1650/1720 ratio for humic acids extracted from the sediments of the Goczalkowice Ibragimov et al. 2010). The interaction of heavy metals with humic acids and the effect of particle size on the ability of their accumulation during the passage of the flood wave need further study. The Institute of Environmental Protection, together with its collaborating institutions plan to conduct further research on the processes occurring during the floods. Acknowledgements The paper was based on the results of the study conducted in the Department of Material Chemistry and Chemical Technology, University of Silesia, under the supervision of Dr. Justyna Polak, to whom we are very grateful. Summary and conclusions It is not clear exactly which physical and chemical processes took place during passing of the flood wave formed on the Vistula River by the Goczalkowice Reservoir, because these are very complex and very dynamic processes, requiring multiannual studies. The conducted spectroscopic analyses of the humic acids extracted from the bottom sediments collected in the Goczalkowice Reservoir prior to and after the flood allow for the following conclusions: 1. Decrease of the free radical concentrations, changes in the values of the g-factor and the 1650/1720 ratio observed after passing of the flood wave indicate the formation of transition metal complexes with humic acids or the occurrence of these metals in the structure of humic acids transported with the flood waters from the flooded area around the Goczalkowice Reservoir. 2. It seems that the variability of organic matter indicators in the Goczalkowice Reservoir after the flood is best reflected by the changes of the free radical concentration, which points to the lower maturity of humic acids from the bottom sediments. This would indicate hampering or rather disturbance of the process with passing of the flood wave. 3. Lack of differences or low variability in the values of the remaining parameters after the flood may result from the simultaneous processes of oxidation and aromatization, which is evidenced by the mutually excluding values of g-factor and free radical concentration.

Journal

Archives of Environmental Protectionde Gruyter

Published: Jun 1, 2016

References