Photocatalytic degradation of volatile chlorinated organic compounds with ozone addition

Photocatalytic degradation of volatile chlorinated organic compounds with ozone addition The decomposition of hydrocarbons using combined advanced oxidation methods is largely considered owing to abundant production of OH radicals and the potential economic advantages. In this study, the synergetic effect of ozonation on photocatalytic oxidation of chloroform and chlorobenzene over expanded graphite-TiO2&ZnO Nano composite was investigated. The effect of introduced ozone concentration and residence time was also examined on removal efficiency. The results showed that the removal efficiency was significantly enhanced by the combined system resulting from the additional oxidation process causing active species to be increased. Increasing the introduced ozone concentration which generates more reactive compounds had a greater effect on the removal efficiency than that of residence time. However, from the mineralization point of view, the residence time had a dominant effect, and the selectivity towards CO2 was dramatically declined when the flow rate increased. Based on these results, the combined system is preferred due to higher removal efficiency and complete mineralization. Introduction Advanced oxidation processes (AOPs) have recently attracted much attention due to their higher ability in mineralizing of volatile organic compounds (VOCs). Among all effective methods, photocatalytic oxidation (PCO) emerged as a promising method to degrade resistant compounds and transform these chemicals to less toxic products. This method includes the formation of UV-induced electron and hole couples and generation of hydroxyl radicals (OH·) (Liu et al. 2006)( Verma et al. 2013). Owing to its simplicity, being under control and classifying as a green process, photocatalysis is a very fascinating technology. Nevertheless, it has a number of problems and disadvantages such as catalyst deactivation, and the creation of harmful intermediates and byproducts. Irreversible deactivation of the catalyst in the case of indole, pyrrole and decamethyltetrasiloxane has been reported. It has also been discovered that the reaction at room temperature leads to rapid deactivation of the TiO2 catalyst resulting from some intermediate compounds such as benzaldehyde and benzoic acid (Huang et al. 2009). The adsorption and oxidation rate can be highly affected by intermediates which are generating during the PCO process. High inlet concentration creates a high concentration of absorbable intermediates, influencing the overall rate of degradation and contributing to the reduction of removal efficiency (Kachina 2008, Mo et al. 2009). The combination of advanced oxidation methods such as UV/Fenton, UV/H2O2 and UV/O3 are being taken into account because of abundant production of OH· radicals and the potential economic advantages (Nawrocki and Kasprzyk-Hordern 2010). The supplementation effect of the combination of UV and ozone deserves further studies (Giri et al. 2008). During UV and ozone hybrid process, strong oxidant holes and OH· radicals can be generated by ozone which increases the overall efficiency and mineralization, and consequently, the final by-products can be highly reduced (QI et al. 2007). The effect of ozone on photocatalaytic oxidation has been investigated in many studies. The results have shown that the catalyst breaks down ozone into atomic oxygen, which is a strong oxidant that causes the removal efficiency to be dramatically increased (Einaga and Futamura 2004, Sanchez et al. 1998, Zsilák et al. 2013). The findings of our unpublished study showed that photocatalytic degradation of chloroform and chlorobenzene over expanded graphite-TiO2&ZnO (EG-TiO2&ZnO) Nano prevent condensation, the air was disturbed by an electromagnet in a container (2 L) and at this stage the temperature was kept constant at 40ºC. After concentration equilibration, the UV lamp was turned on for 20 minutes in all experiments, and then the rate of pollutants degradation was measured. A fixed packed-bed PCO aluminum tube reactor (inner diameter 30 mm, length 300 mm) was used. Axially, inside the reactor, an 8 W UV lamp of 253.7 nm (Philips TUV 8W G8 T5 Bulb), 15 × 300 mm, was placed. 100 mm of the reactor length was filled with 0.3 g of EG-TiO2&ZnO Nano composite between the outer wall of the lamp and the inner wall of the reactor so that the space around the lamp was totally packed with the composite (Fig. 2). Analytical method Sampling was conducted using a gastight syringe (Hamilton, United States) of embedded sampling ports before and after the PCO process. A gas chromatograph (GC-2010, Shimadzu, Japan) equipped with a hydrogen flame ionization detector (FID) and 25 m long SGE capillary column (fused sillica) was used to detect the contaminants at the inlet and outlet of PCO reactor. A gas chromatograph/mass spectrometer (Varian, CP-3800, United States) was also applied to determine some organic by-products. The removal efficiency of the PCO process is expressed in equation 1. composite was a function of flow rate and concentration. The effect of the latter is especially detrimental. This is mainly due to the saturation of catalyst active sites, generation of intermediates and competitive reaction with pollutants for binding the active sites of the catalyst. The objective of this study was to investigate the effect of PCO on the removal of chloroform and chlorobenzene vapors in the presence of ozone. The effect of ozone concentration and residence time on removal efficiency was also explored. Special attention was given to the by-products and selectivity towards CO2. Material and methods Experimental procedure and conditions The experimental setup is illustrated in Fig. 1. The normal air was subjected to flow through the experimental system by a compressor and filtered for contaminants and aerosols to be removed. Flow rates of 0.3, 0.6 and 1.2 L/min were chosen for this study, corresponding to residence times of 0.4, 0.2 and 0.1 second respectively. A compact ozone generator (COG1A, ARDA, and France) producing ozone at three different concentrations of 2, 4 and 8 mg/L was used to feed the system by ozone. Chloroform and chlorobenzene were injected by a syringe pump (SP-510, JMS) in two different concentrations (250 and 500 ppm in air). In order to provide enough mixture and Fig. 1. Schematic diagram of the experimental setup Fig. 2. Schematic overview of PCO reactor (1) Where Cin and Cout are the inlet and outlet concentrations of chloroform and chlorobenzene, respectively. CO2 produced in the reactor was monitored using a CO2 detector (Kimo-AQ100, United Kingdom). The selectivity towards CO2 for chloroform and chlorobenzene decomposition was calculated as follows: (2) China) converted to the expanded graphite. The expanded graphite was then added to the combined sol and placed in a dark room for two days. The smooth and dried samples were then calcined in an oven (400°C for 2 h) (Shahna et al. 2015, Shahna et al. 2016). Characterizations The properties of the synthesized EG-TiO2&ZnO Nano composite have been identified through different analytical techniques. The morphologies and microstructures of Nano composite were observed using SEM (TESCAN, MIRA3, unites state). XRD analysis was carried out over the 2-theta range of 2­90° with APD 2000 XRD (Italy) using CU radiation (1.54 A°) for crystal phase identification of Nano composite. In order to measure the elements in Nano composite, EDX technique was applied. (3) Where Cin and Cout are the inlet and outlet concentrations, respectively. Synthesis of EG-TiO2&ZnO Nano composite The EG-TiO2&ZnO Nano composite preparation technique was sol-gel. Firstly, TiO2 sol was prepared applying titaniumn-butoxide as the precursor. 2.04 ml of Ti (OBu)4 diluted with 36.64 ml of PrOH as a solvent. Then, the resultant mixture was stirred at room temperature for 1h. Afterwards, acetyl acetone as stabilizer was added dropwise to the mixed solution under stirring and the solution was stirred again for 2 h. Then, a HNO3 aqueous solution was added under stirring, ensuring a pH of about 2. Finally, the solution was refluxed for 8 h to obtain crystalline anatase sol (Yan and Chunwei 2006, Shahna et al, 2015, Shahna et al, 2016). To prepare ZnO sol, 8.76 g zinc acetate dehydrate was dissolved in 200 ml of ethanol. Next, 5.96 g of Tri Ethanol Amine was added to the solution. After one h, the solution was removed and ultrasonically treated for 30 min at 40°C (Pal and Sharon 2002) (Shahna et al. 2015, Shahna et al. 2016). The TiO2 and ZnO sols were combined in equal amounts. Using a thermal shock method (thermal shock in the range of 1000­1050°C for 30 seconds), the expandable graphite (Beijing invention biology engineering & new materials, Results and discussion Characteristics of EG-TiO2&ZnO Nano composite Fig. 3 shows the XRD patterns of the EG-TiO2&ZnO Nano composite after heat treatment at 400 °C for 2 h. It is evident from the figure that the only detected phase for TiO2 was anatase, and no rutile and brookite phases were observed. As it has been described in the literature, the anatase phase formed below 500°C transforms to a rutile-type structure above 600°C and is changed into single phase of rutile at 700~900°C (Inagaki et al. 2003, Chen et al. 2006a, Oh et al. 2010, Chen et al. 2006b). Major peaks for TiO2 particles were detected at 2-theta degrees of 25.2°, 38.5°, 53.8°, 62.6°, 68.7° and 76.0°. They were all assigned to diffraction peaks of the anatase TiO2 (JCPDS No.21-1272). For ZnO samples as shown in Fig. 3, major peaks were detected at 2-theta degrees of 31.7°, 34.4°, 36.2°, 47.5°, 56.6°, 67.9° and 89.6° which all were assigned to diffraction peaks of the ZnO (JCPDS No.70-2551). All diffraction peaks correspond to the standard diffraction pattern except for 2=26.5° which is related to the EG itself (Wu et al. 2011). This most intense peak of the template overlapped strongly the anatase TiO2 refractogram at 2 of 25.2°. SEM observations confirmed the results of the XRD analysis. It showed that both TiO2 and ZnO particles have been Fig. 3. XRD patterns of the EG-TiO2&ZnO Nano composite concentration of pollutant close to the catalyst surface, researchers have employed an adsorbent as a support (Lu et al. 2012). The results of the present study demonstrated that chloroform and chlorobenzene destruction efficiency was a function of the inlet concentration and significantly increased when the pollutants feeding was raised. For chloroform, by raising the concentration from 250 to 500 ppm, the efficiency went up by 6%, 8% and 4% at flow rates of 0.3, 0.6 and 1.2 L/min, respectively. These findings showed that destruction efficiency was reduced with increasing concentrations. This can be attributed to saturation of the catalyst active sites by the pollutants and production of more intermediates at high concentrations. PCO reaction is divided into several more minor reactions that follow each other, the reaction products of each of these steps are called intermediate. These intermediates may be placed on the active sites and disrupt the PCO process (Mo et al. 2009). There were multiple processes in photocalaytic ozonation system, including PCO, ozone photolysis (UV/O3), and catalytic ozonation (O3/EG-TiO2&ZnO). In O3-PCO process, chloroform and chlorobenzene oxidation occurred not only on the surface of photocatalyst (e.g., in the PCO and O3/EG-TiO2&ZnO sub process) but also in the gas phase (e.g., UV/O3) (Huang, 2010). In addition, the presence of ozone increased the active species (OH·, O·). Eq. 4 shows that the pathway of OH· radicals are the dominant strong oxidant in the PCO process. Equations 5 and 6 show the pathway of coated on the surface of EG. Fig. 4 represents the SEM images of the EG loaded by TiO2 and ZnO. It was clearly seen that the EG structure was changed and broken up to small fragments. It was also seen that TiO2 and ZnO particles were effectively spread on the surface of the EG layers as single or multi-layer. The Nano metric scale of TiO2 and ZnO particles is evident from the figures. It is also seen that the size of ZnO particles (Square shape) are larger than that of TiO2 particles (spherical shape). The larger size of ZnO particles can be the result of agglomeration (Carp et al. 2004). Table. 1 shows the EDX elemental microanalysis (wt% and At%) of EG-TiO2&ZnO Nano composite. The data showed that EG-TiO2&ZnO Nano composite contained four kinds of main elements, C, O, Ti and Zn. It is obvious that wt% (26.86%) of Ti was much more than of Zn wt% (12.11%) in the EG-TiO2&ZnO Nano composite and the catalyst was coated by TiO2 much more than ZnO particles. These phenomena may be the consequence of smaller size of TiO2 nanocrystals. Destruction of chloroform and chlorobenzene Chloroform and chlorobenzene were degraded in O3-PCO processes. The removal efficiency, as a function of initial flow rate, ozone and pollutant (Chloroform and Chlorobenzene) concentrations, has been shown in Fig. 5. Best efficiency of the photocatalyst occurred at high concentrations of the pollutant. In order to increase the Fig. 4. The SEM micrograph of EG-TiO2&ZnO Nano composite: efficiency in nanospace 20 m Table. 1. EDX Elemental Microanalysis (wt% and At%) of the EG-TiO2&ZnO Nano composite Elements C Wt% At% 45.54 68.93 O 13.62 15.45 Ti 26.86 9.98 Zn 12.11 3.86 Others 1.87 1.78 Total 100 100 additional oxidant agents (O·, OH·) formation in the O3-PCO system (Huang 2010). (4) (5) (4) Therefore, in the O3-PCO system, two degradation processes are added to the PCO and more hydroxyl radicals and atomic oxygen are created which are considered as strong oxidants. Given these changes in O3-PCO system, the likelihood of the saturation of active sites of the catalyst is reduced. The generated intermediates are also oxidized and removed from the catalyst surface; hence, more active sites of the catalyst are exposed to the pollutants and the removal efficiency increases by raising the inlet concentration. The results showed that the degree of removal of the chloroform was much higher than that of chlorobenzene, explaining difference in the chemical structure of these compounds. With regard to the chemical structure of the compounds and, in fact, the quantity of required energy for breaking of each band, (Karatum 2012), the degradation of chlorobenzene was much more energetic; the chloroform removal efficiency therefore was much higher. Fig. 6 shows the increased level of removal efficiency in the O3-PCO hybrid system relative to PCO alone. As can be seen, the rate of increase for the concentrations of 500 ppm was greater than that of 250 ppm resulting from the saturation behavior of the PCO alone. However, with O3-PCO hybrid process, due to a rise in the generation of oxidizing agents, optimal concentration is increased and therefore by raising the concentration the removal efficiency is maximized. According to previous works, the removal rate of contaminants is decreased by increasing the flow rate, particularly at low concentrations (Lu et al. 2012). Our results were supported by the literature, indicating that the increase of flow rate leads to higher removal efficiency. For example, the chloroform removal efficiency went up from 3 to 13% when the flow rate increased from 0.3 to 0.6 and then to 1.2 L/min. At the same time, for chlorobenzene, the removal efficiency increased from 7 to 11%. The effect of flow rate on removal efficiency in this study can mainly be attributed to the more amount of ozone introduced to the reactor. The concentrations of the ozone introduced to the reactor at flow rates of 0.3, 0.6 and 1.2 L/min were 2, 4 and 8 mg/L respectively. Going up the concentration of the introduced ozone leads to higher removal efficiency through generating more active species such as O·, OH· (Huang 2010). Fig. 5. Removal efficiency of chloroform and chlorobenzene Fig. 6. Increase the removal efficiency of chloroform and chlorobenzene by O3-PCO relation to PCO In order to explain the lesser CO2 selectivity of chlorobenzene compared to chloroform, the three following causes would be noted: 1 ­ chlorobenzene is more difficult to be degraded due to the aromatic ring which has less reactivity, 2 ­ intermediate compounds are generated in destruction process of chlorobenzene compared to chloroform, 3 ­ chlorobenzene requires higher amounts of oxidants than chloroform for oxidation (Huang 2010). Assuming production of CO2, H2O, and CL, the complete oxidation of a CHCL3 molecule requires 5 OH· molecules or 5/2 O· molecules, whereas the figures for the complete oxidation of a chlorobenzene molecule rises up to 29 OH· or 29/2 O· as described in equations 7­10. (7) (8) (9) (10) Although the degradation efficiency is raised with increasing the concentration, the oxidant agents' levels According to the literature, increasing the flow rate raises the space velocity and thereby reduces the degradation efficiency. However, in this study, increasing the ozone concentration was much effective than the space velocity. It can be clearly seen from figure 7 that the removal efficiency of O3-PCO combined system increased much more than that of PCO alone when the flow rate raised up. CO2 selectivity and byproducts The catalytic ozonation is an effective method for destruction of VOCs. From the advantages of this method conversion of VOCs into less harmful materials such as water and carbon dioxide can be noted (Rezaei and Soltan 2012). Einaga and Futamura (2007), conducted a study and tried to determine the products of catalytic ozonation of benzene, and concluded that CO2 and CO were the predominant reaction products. The CO2 selectivity declined with increasing the flow rate and introduced concentration (Fig. 7). This reduction was greater for chlorobenzene. Although increasing the flow rate increased the generated oxidants of ozone, the residence time of contaminants in the reactor declined and as a consequence there would be not enough time for the completion of oxidation and mineralization reactions. Therefore, the pollutants were just converted to intermediates and not the final products like CO2. Fig. 7. CO2 selectivity of Chloroform and Chlorobenzene Fig. 8. Increase the CO2 selectivity of chloroform and chlorobenzene by O3-PCO process toward PCO process are not sufficient to guarantee complete oxidation and the chemicals are just converted to intermediates. Fig. 8 shows the amount of increased selectivity of CO2 by the hybrid system compared to the PCO process. The results showed that the selectivity patterns of chloroform and chlorobenzene were not similar. The increase level for chloroform and chlorobenzene was similar at flow rates of 0.3 L/min and concentration of 250 ppm. However, at this flow rate with climbing up the concentration, the CO2 selectivity for chloroform decomposition increased. At flow rates of 0.6 and 1.2 L/min, raising the concentration had a little effect on increasing the CO2 selectivity of chloroform, while the selectivity of CO2 for chlorobenzene was induced significantly mainly due to the deficiency of oxidant agents for the complete oxidation of chlorobenzene. Conclusion Chloroform and chlorobenzene degradation under environmental indoor conditions was achieved by photocatalytic oxidation combined with ozone. From a removal efficiency point of view, the combined system led to better removal efficiency compared to PCO alone. In this study the effect of raising the introduced ozone concentration versus increasing the resident time was investigated. The results showed that raising the introduced ozone concentration and generating more reactive species, has a greater effect on the removal efficiency than for increasing the residence time. The removal efficiency therefore went up with increasing the flow rate which was accompanied by the introduced ozone concentration. The results showed that the removal efficiency increased with raising the introduced concentration. This is mainly due to oxidation of the intermediate compounds and adsorbed pollutants on the active sites of catalyst by additional oxidant agents generated through ozone feeding, resulting in regenerating the catalyst active sites. Therefore, the catalyst showed saturation behavior at higher concentrations and consequently the removal efficiency increased. From a mineralization point of view, the selectivity of CO2 in the combined system increased by about 13% in comparison to photocatalytic oxidation alone. This is generally due to generation of more oxidant agents in combined system, leading to higher mineralization of pollutants yielding CO2 and H2O. Increasing the residence time had a greater effect on the selectivity of CO2 than the introduced ozone concentration. Although raising the pollutants concentration leads to higher removal efficiency, the perfect mineralization of compounds is not implemented in high concentrations. Based on these results, the combined system is highly preferred due to higher removal efficiency, complete mineralization and the formation of lower amounts of harmful byproducts. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Archives of Environmental Protection de Gruyter

Photocatalytic degradation of volatile chlorinated organic compounds with ozone addition

Loading next page...
 
/lp/de-gruyter/photocatalytic-degradation-of-volatile-chlorinated-organic-compounds-3vhjqD5GkC
Publisher
de Gruyter
Copyright
Copyright © 2017 by the
ISSN
2083-4810
eISSN
2083-4810
DOI
10.1515/aep-2017-0006
Publisher site
See Article on Publisher Site

Abstract

The decomposition of hydrocarbons using combined advanced oxidation methods is largely considered owing to abundant production of OH radicals and the potential economic advantages. In this study, the synergetic effect of ozonation on photocatalytic oxidation of chloroform and chlorobenzene over expanded graphite-TiO2&ZnO Nano composite was investigated. The effect of introduced ozone concentration and residence time was also examined on removal efficiency. The results showed that the removal efficiency was significantly enhanced by the combined system resulting from the additional oxidation process causing active species to be increased. Increasing the introduced ozone concentration which generates more reactive compounds had a greater effect on the removal efficiency than that of residence time. However, from the mineralization point of view, the residence time had a dominant effect, and the selectivity towards CO2 was dramatically declined when the flow rate increased. Based on these results, the combined system is preferred due to higher removal efficiency and complete mineralization. Introduction Advanced oxidation processes (AOPs) have recently attracted much attention due to their higher ability in mineralizing of volatile organic compounds (VOCs). Among all effective methods, photocatalytic oxidation (PCO) emerged as a promising method to degrade resistant compounds and transform these chemicals to less toxic products. This method includes the formation of UV-induced electron and hole couples and generation of hydroxyl radicals (OH·) (Liu et al. 2006)( Verma et al. 2013). Owing to its simplicity, being under control and classifying as a green process, photocatalysis is a very fascinating technology. Nevertheless, it has a number of problems and disadvantages such as catalyst deactivation, and the creation of harmful intermediates and byproducts. Irreversible deactivation of the catalyst in the case of indole, pyrrole and decamethyltetrasiloxane has been reported. It has also been discovered that the reaction at room temperature leads to rapid deactivation of the TiO2 catalyst resulting from some intermediate compounds such as benzaldehyde and benzoic acid (Huang et al. 2009). The adsorption and oxidation rate can be highly affected by intermediates which are generating during the PCO process. High inlet concentration creates a high concentration of absorbable intermediates, influencing the overall rate of degradation and contributing to the reduction of removal efficiency (Kachina 2008, Mo et al. 2009). The combination of advanced oxidation methods such as UV/Fenton, UV/H2O2 and UV/O3 are being taken into account because of abundant production of OH· radicals and the potential economic advantages (Nawrocki and Kasprzyk-Hordern 2010). The supplementation effect of the combination of UV and ozone deserves further studies (Giri et al. 2008). During UV and ozone hybrid process, strong oxidant holes and OH· radicals can be generated by ozone which increases the overall efficiency and mineralization, and consequently, the final by-products can be highly reduced (QI et al. 2007). The effect of ozone on photocatalaytic oxidation has been investigated in many studies. The results have shown that the catalyst breaks down ozone into atomic oxygen, which is a strong oxidant that causes the removal efficiency to be dramatically increased (Einaga and Futamura 2004, Sanchez et al. 1998, Zsilák et al. 2013). The findings of our unpublished study showed that photocatalytic degradation of chloroform and chlorobenzene over expanded graphite-TiO2&ZnO (EG-TiO2&ZnO) Nano prevent condensation, the air was disturbed by an electromagnet in a container (2 L) and at this stage the temperature was kept constant at 40ºC. After concentration equilibration, the UV lamp was turned on for 20 minutes in all experiments, and then the rate of pollutants degradation was measured. A fixed packed-bed PCO aluminum tube reactor (inner diameter 30 mm, length 300 mm) was used. Axially, inside the reactor, an 8 W UV lamp of 253.7 nm (Philips TUV 8W G8 T5 Bulb), 15 × 300 mm, was placed. 100 mm of the reactor length was filled with 0.3 g of EG-TiO2&ZnO Nano composite between the outer wall of the lamp and the inner wall of the reactor so that the space around the lamp was totally packed with the composite (Fig. 2). Analytical method Sampling was conducted using a gastight syringe (Hamilton, United States) of embedded sampling ports before and after the PCO process. A gas chromatograph (GC-2010, Shimadzu, Japan) equipped with a hydrogen flame ionization detector (FID) and 25 m long SGE capillary column (fused sillica) was used to detect the contaminants at the inlet and outlet of PCO reactor. A gas chromatograph/mass spectrometer (Varian, CP-3800, United States) was also applied to determine some organic by-products. The removal efficiency of the PCO process is expressed in equation 1. composite was a function of flow rate and concentration. The effect of the latter is especially detrimental. This is mainly due to the saturation of catalyst active sites, generation of intermediates and competitive reaction with pollutants for binding the active sites of the catalyst. The objective of this study was to investigate the effect of PCO on the removal of chloroform and chlorobenzene vapors in the presence of ozone. The effect of ozone concentration and residence time on removal efficiency was also explored. Special attention was given to the by-products and selectivity towards CO2. Material and methods Experimental procedure and conditions The experimental setup is illustrated in Fig. 1. The normal air was subjected to flow through the experimental system by a compressor and filtered for contaminants and aerosols to be removed. Flow rates of 0.3, 0.6 and 1.2 L/min were chosen for this study, corresponding to residence times of 0.4, 0.2 and 0.1 second respectively. A compact ozone generator (COG1A, ARDA, and France) producing ozone at three different concentrations of 2, 4 and 8 mg/L was used to feed the system by ozone. Chloroform and chlorobenzene were injected by a syringe pump (SP-510, JMS) in two different concentrations (250 and 500 ppm in air). In order to provide enough mixture and Fig. 1. Schematic diagram of the experimental setup Fig. 2. Schematic overview of PCO reactor (1) Where Cin and Cout are the inlet and outlet concentrations of chloroform and chlorobenzene, respectively. CO2 produced in the reactor was monitored using a CO2 detector (Kimo-AQ100, United Kingdom). The selectivity towards CO2 for chloroform and chlorobenzene decomposition was calculated as follows: (2) China) converted to the expanded graphite. The expanded graphite was then added to the combined sol and placed in a dark room for two days. The smooth and dried samples were then calcined in an oven (400°C for 2 h) (Shahna et al. 2015, Shahna et al. 2016). Characterizations The properties of the synthesized EG-TiO2&ZnO Nano composite have been identified through different analytical techniques. The morphologies and microstructures of Nano composite were observed using SEM (TESCAN, MIRA3, unites state). XRD analysis was carried out over the 2-theta range of 2­90° with APD 2000 XRD (Italy) using CU radiation (1.54 A°) for crystal phase identification of Nano composite. In order to measure the elements in Nano composite, EDX technique was applied. (3) Where Cin and Cout are the inlet and outlet concentrations, respectively. Synthesis of EG-TiO2&ZnO Nano composite The EG-TiO2&ZnO Nano composite preparation technique was sol-gel. Firstly, TiO2 sol was prepared applying titaniumn-butoxide as the precursor. 2.04 ml of Ti (OBu)4 diluted with 36.64 ml of PrOH as a solvent. Then, the resultant mixture was stirred at room temperature for 1h. Afterwards, acetyl acetone as stabilizer was added dropwise to the mixed solution under stirring and the solution was stirred again for 2 h. Then, a HNO3 aqueous solution was added under stirring, ensuring a pH of about 2. Finally, the solution was refluxed for 8 h to obtain crystalline anatase sol (Yan and Chunwei 2006, Shahna et al, 2015, Shahna et al, 2016). To prepare ZnO sol, 8.76 g zinc acetate dehydrate was dissolved in 200 ml of ethanol. Next, 5.96 g of Tri Ethanol Amine was added to the solution. After one h, the solution was removed and ultrasonically treated for 30 min at 40°C (Pal and Sharon 2002) (Shahna et al. 2015, Shahna et al. 2016). The TiO2 and ZnO sols were combined in equal amounts. Using a thermal shock method (thermal shock in the range of 1000­1050°C for 30 seconds), the expandable graphite (Beijing invention biology engineering & new materials, Results and discussion Characteristics of EG-TiO2&ZnO Nano composite Fig. 3 shows the XRD patterns of the EG-TiO2&ZnO Nano composite after heat treatment at 400 °C for 2 h. It is evident from the figure that the only detected phase for TiO2 was anatase, and no rutile and brookite phases were observed. As it has been described in the literature, the anatase phase formed below 500°C transforms to a rutile-type structure above 600°C and is changed into single phase of rutile at 700~900°C (Inagaki et al. 2003, Chen et al. 2006a, Oh et al. 2010, Chen et al. 2006b). Major peaks for TiO2 particles were detected at 2-theta degrees of 25.2°, 38.5°, 53.8°, 62.6°, 68.7° and 76.0°. They were all assigned to diffraction peaks of the anatase TiO2 (JCPDS No.21-1272). For ZnO samples as shown in Fig. 3, major peaks were detected at 2-theta degrees of 31.7°, 34.4°, 36.2°, 47.5°, 56.6°, 67.9° and 89.6° which all were assigned to diffraction peaks of the ZnO (JCPDS No.70-2551). All diffraction peaks correspond to the standard diffraction pattern except for 2=26.5° which is related to the EG itself (Wu et al. 2011). This most intense peak of the template overlapped strongly the anatase TiO2 refractogram at 2 of 25.2°. SEM observations confirmed the results of the XRD analysis. It showed that both TiO2 and ZnO particles have been Fig. 3. XRD patterns of the EG-TiO2&ZnO Nano composite concentration of pollutant close to the catalyst surface, researchers have employed an adsorbent as a support (Lu et al. 2012). The results of the present study demonstrated that chloroform and chlorobenzene destruction efficiency was a function of the inlet concentration and significantly increased when the pollutants feeding was raised. For chloroform, by raising the concentration from 250 to 500 ppm, the efficiency went up by 6%, 8% and 4% at flow rates of 0.3, 0.6 and 1.2 L/min, respectively. These findings showed that destruction efficiency was reduced with increasing concentrations. This can be attributed to saturation of the catalyst active sites by the pollutants and production of more intermediates at high concentrations. PCO reaction is divided into several more minor reactions that follow each other, the reaction products of each of these steps are called intermediate. These intermediates may be placed on the active sites and disrupt the PCO process (Mo et al. 2009). There were multiple processes in photocalaytic ozonation system, including PCO, ozone photolysis (UV/O3), and catalytic ozonation (O3/EG-TiO2&ZnO). In O3-PCO process, chloroform and chlorobenzene oxidation occurred not only on the surface of photocatalyst (e.g., in the PCO and O3/EG-TiO2&ZnO sub process) but also in the gas phase (e.g., UV/O3) (Huang, 2010). In addition, the presence of ozone increased the active species (OH·, O·). Eq. 4 shows that the pathway of OH· radicals are the dominant strong oxidant in the PCO process. Equations 5 and 6 show the pathway of coated on the surface of EG. Fig. 4 represents the SEM images of the EG loaded by TiO2 and ZnO. It was clearly seen that the EG structure was changed and broken up to small fragments. It was also seen that TiO2 and ZnO particles were effectively spread on the surface of the EG layers as single or multi-layer. The Nano metric scale of TiO2 and ZnO particles is evident from the figures. It is also seen that the size of ZnO particles (Square shape) are larger than that of TiO2 particles (spherical shape). The larger size of ZnO particles can be the result of agglomeration (Carp et al. 2004). Table. 1 shows the EDX elemental microanalysis (wt% and At%) of EG-TiO2&ZnO Nano composite. The data showed that EG-TiO2&ZnO Nano composite contained four kinds of main elements, C, O, Ti and Zn. It is obvious that wt% (26.86%) of Ti was much more than of Zn wt% (12.11%) in the EG-TiO2&ZnO Nano composite and the catalyst was coated by TiO2 much more than ZnO particles. These phenomena may be the consequence of smaller size of TiO2 nanocrystals. Destruction of chloroform and chlorobenzene Chloroform and chlorobenzene were degraded in O3-PCO processes. The removal efficiency, as a function of initial flow rate, ozone and pollutant (Chloroform and Chlorobenzene) concentrations, has been shown in Fig. 5. Best efficiency of the photocatalyst occurred at high concentrations of the pollutant. In order to increase the Fig. 4. The SEM micrograph of EG-TiO2&ZnO Nano composite: efficiency in nanospace 20 m Table. 1. EDX Elemental Microanalysis (wt% and At%) of the EG-TiO2&ZnO Nano composite Elements C Wt% At% 45.54 68.93 O 13.62 15.45 Ti 26.86 9.98 Zn 12.11 3.86 Others 1.87 1.78 Total 100 100 additional oxidant agents (O·, OH·) formation in the O3-PCO system (Huang 2010). (4) (5) (4) Therefore, in the O3-PCO system, two degradation processes are added to the PCO and more hydroxyl radicals and atomic oxygen are created which are considered as strong oxidants. Given these changes in O3-PCO system, the likelihood of the saturation of active sites of the catalyst is reduced. The generated intermediates are also oxidized and removed from the catalyst surface; hence, more active sites of the catalyst are exposed to the pollutants and the removal efficiency increases by raising the inlet concentration. The results showed that the degree of removal of the chloroform was much higher than that of chlorobenzene, explaining difference in the chemical structure of these compounds. With regard to the chemical structure of the compounds and, in fact, the quantity of required energy for breaking of each band, (Karatum 2012), the degradation of chlorobenzene was much more energetic; the chloroform removal efficiency therefore was much higher. Fig. 6 shows the increased level of removal efficiency in the O3-PCO hybrid system relative to PCO alone. As can be seen, the rate of increase for the concentrations of 500 ppm was greater than that of 250 ppm resulting from the saturation behavior of the PCO alone. However, with O3-PCO hybrid process, due to a rise in the generation of oxidizing agents, optimal concentration is increased and therefore by raising the concentration the removal efficiency is maximized. According to previous works, the removal rate of contaminants is decreased by increasing the flow rate, particularly at low concentrations (Lu et al. 2012). Our results were supported by the literature, indicating that the increase of flow rate leads to higher removal efficiency. For example, the chloroform removal efficiency went up from 3 to 13% when the flow rate increased from 0.3 to 0.6 and then to 1.2 L/min. At the same time, for chlorobenzene, the removal efficiency increased from 7 to 11%. The effect of flow rate on removal efficiency in this study can mainly be attributed to the more amount of ozone introduced to the reactor. The concentrations of the ozone introduced to the reactor at flow rates of 0.3, 0.6 and 1.2 L/min were 2, 4 and 8 mg/L respectively. Going up the concentration of the introduced ozone leads to higher removal efficiency through generating more active species such as O·, OH· (Huang 2010). Fig. 5. Removal efficiency of chloroform and chlorobenzene Fig. 6. Increase the removal efficiency of chloroform and chlorobenzene by O3-PCO relation to PCO In order to explain the lesser CO2 selectivity of chlorobenzene compared to chloroform, the three following causes would be noted: 1 ­ chlorobenzene is more difficult to be degraded due to the aromatic ring which has less reactivity, 2 ­ intermediate compounds are generated in destruction process of chlorobenzene compared to chloroform, 3 ­ chlorobenzene requires higher amounts of oxidants than chloroform for oxidation (Huang 2010). Assuming production of CO2, H2O, and CL, the complete oxidation of a CHCL3 molecule requires 5 OH· molecules or 5/2 O· molecules, whereas the figures for the complete oxidation of a chlorobenzene molecule rises up to 29 OH· or 29/2 O· as described in equations 7­10. (7) (8) (9) (10) Although the degradation efficiency is raised with increasing the concentration, the oxidant agents' levels According to the literature, increasing the flow rate raises the space velocity and thereby reduces the degradation efficiency. However, in this study, increasing the ozone concentration was much effective than the space velocity. It can be clearly seen from figure 7 that the removal efficiency of O3-PCO combined system increased much more than that of PCO alone when the flow rate raised up. CO2 selectivity and byproducts The catalytic ozonation is an effective method for destruction of VOCs. From the advantages of this method conversion of VOCs into less harmful materials such as water and carbon dioxide can be noted (Rezaei and Soltan 2012). Einaga and Futamura (2007), conducted a study and tried to determine the products of catalytic ozonation of benzene, and concluded that CO2 and CO were the predominant reaction products. The CO2 selectivity declined with increasing the flow rate and introduced concentration (Fig. 7). This reduction was greater for chlorobenzene. Although increasing the flow rate increased the generated oxidants of ozone, the residence time of contaminants in the reactor declined and as a consequence there would be not enough time for the completion of oxidation and mineralization reactions. Therefore, the pollutants were just converted to intermediates and not the final products like CO2. Fig. 7. CO2 selectivity of Chloroform and Chlorobenzene Fig. 8. Increase the CO2 selectivity of chloroform and chlorobenzene by O3-PCO process toward PCO process are not sufficient to guarantee complete oxidation and the chemicals are just converted to intermediates. Fig. 8 shows the amount of increased selectivity of CO2 by the hybrid system compared to the PCO process. The results showed that the selectivity patterns of chloroform and chlorobenzene were not similar. The increase level for chloroform and chlorobenzene was similar at flow rates of 0.3 L/min and concentration of 250 ppm. However, at this flow rate with climbing up the concentration, the CO2 selectivity for chloroform decomposition increased. At flow rates of 0.6 and 1.2 L/min, raising the concentration had a little effect on increasing the CO2 selectivity of chloroform, while the selectivity of CO2 for chlorobenzene was induced significantly mainly due to the deficiency of oxidant agents for the complete oxidation of chlorobenzene. Conclusion Chloroform and chlorobenzene degradation under environmental indoor conditions was achieved by photocatalytic oxidation combined with ozone. From a removal efficiency point of view, the combined system led to better removal efficiency compared to PCO alone. In this study the effect of raising the introduced ozone concentration versus increasing the resident time was investigated. The results showed that raising the introduced ozone concentration and generating more reactive species, has a greater effect on the removal efficiency than for increasing the residence time. The removal efficiency therefore went up with increasing the flow rate which was accompanied by the introduced ozone concentration. The results showed that the removal efficiency increased with raising the introduced concentration. This is mainly due to oxidation of the intermediate compounds and adsorbed pollutants on the active sites of catalyst by additional oxidant agents generated through ozone feeding, resulting in regenerating the catalyst active sites. Therefore, the catalyst showed saturation behavior at higher concentrations and consequently the removal efficiency increased. From a mineralization point of view, the selectivity of CO2 in the combined system increased by about 13% in comparison to photocatalytic oxidation alone. This is generally due to generation of more oxidant agents in combined system, leading to higher mineralization of pollutants yielding CO2 and H2O. Increasing the residence time had a greater effect on the selectivity of CO2 than the introduced ozone concentration. Although raising the pollutants concentration leads to higher removal efficiency, the perfect mineralization of compounds is not implemented in high concentrations. Based on these results, the combined system is highly preferred due to higher removal efficiency, complete mineralization and the formation of lower amounts of harmful byproducts.

Journal

Archives of Environmental Protectionde Gruyter

Published: Mar 1, 2017

References