The procedure for simultaneous extraction from soil and determination by means of GCECD insecticides: , , and herbicide: was worked out. The proposed GCECD technique provides limits of detection in range 12 g/mL 18 g/mL and 2 g/mL, for insecticides and , respectively. Two different types of extraction: microwave assisted extraction (MAE) and ultrasound assisted extraction (UAE) with different solvents were tested to choose the procedure that provides the highest recoveries of analytes and low detection limits, typical for trace analysis (100 ppm or 100 mg/g, IUPAC). On the basis of recoveries and precision both extraction methods were compared. The insecticides recovery from soil samples obtained by UAE were in range 4085%, coefficient of variation (CV): 1.35.0%, whereas for recovery was below 15% (CV: 818%). The most efficient and precise extraction procedure turned out to be MAE with n-hexane: acetone. The recoveries were in range 7085% for insecticides and 84% for , CV: 0.42.2% and 5.3% for insecticides and , respectively. The presented MAEGCECD procedure enables extraction and determination of , , and in soil samples with high recoveries, precision and limits of detections in range 6 ng/g 8 ng/g in the case of insecticides and 1.5 ng/g for . The MAEGCECD procedure was applied for the above mentioned pesticides determination in environmental samples. Soils were collected in agricultural as well as rural areas in Poland. In all cases was determined in concentration range: 0.0187 mg/g 0.1107 mg/g. and was detected in soil samples from two locations. INTRODUCTION Agriculture plays a key role in the world. Fast industrial progress and the reduction of the rural area, force the increase and effectiveness of cultivation. To cope with these requirements, the application of pesticides is necessary. Chloroorganic insecticides are used for insects annihilation in agriculture, forests and households. Since they are toxic for human and persistent in the environment, they were withdrawn in many countries, among others in Poland. Nevertheless, they are present in the environment because of their stability (30 years) and threat to the environment [7, 12, 21, 24, 41]. Herbicides are used to fight weeds. One of the most common group of herbicides are triazines, used in crops, especially corn and potatoes cultivations. These compounds as well as their degradation products are stable in the soil. (herbicide), , and (insecticide) are the objects of this study. Their physical-chemical properties are listed in Table 1 [11, 27]. , and are soluble in fats. They are persistent in the environment (half-life of 2 years) [13]. They are carcinogenic, cause dermatological diseases, coronary heart disease, arteriosclerosis, hypertension and diabetes [21, 30, 41]. has been applied on agricultural soil since 1950, being one of the most widely used herbicides in the world. The persistence of and its ability of translocation in the environment are key factors influencing its potential to contaminate the terrestrial and aquatic environments. Due to its possible carcinogenic, endocrine disrupter and teratogen properties, has been classified as one of the major target anthropogenic pollutants [12, 29, 31, 43]. Even though, is withdrawn from application in the European Union, it is still detected in European environment. Monitoring of the contamination level of environment underlies the assessment of the threat of human health. Therefore, sensitive and selective analytical methods for the determination of , , and residues in soil matrices are desirable. Pressurised liquid extraction (PLE) and microwave-assisted extraction (MAE) are techniques that can be used instead of shake flask or Soxhlet extraction. They are rapid and require fewer solvents in comparison to traditional liquid solid extraction. Ultrasound assisted extraction (UAE) provides an efficient contact between the solid and the extractant, usually resulting in a good recovery of the analyte. Tadeo [50] established, that the efficiency of UAE was dependent on the type of solvent, temperature, character of analytes and sample matrix. Therefore, it is necessary to optimise the extraction process taking into account the above mentioned parameters. Microwave assisted extraction provides high recoveries of analytes in a short time, is easy to automation, however, there is a risk of decomposition of compounds sensitive to temperature [14]. Determination of pesticides in soil is a complex task, it usually includes four stages: soil pre-treatment (drying, grinding, sieving), analytes extraction from the matrix, clean up the extract and the analyse identification and quantitative analyse of compounds. The recovery of analytes is influenced by the following soil factors: granulometric composition, mineral and organic matter content (mainly fulvic and humic acids) as well as pH of soil [38, 39]. Ultrasound assisted extraction is a useful tool for , and extraction from soil samples. According to [40, 51], the above mentioned insecticides were extracted from the soil samples with the mixture of petroleum ether and acetone or dichloromethane, for the first extraction solvent the additional clean up was conducted on Al2O3 sorbent. The analytes recoveries were between 93101%. Microwave assisted extraction is another extraction technique that enables fast separation of pesticides from soil matrix. Concha-Graña and coworkers [10] applied the mixture of hexane acetone for , and extraction from soil. Subsequently, the extract was cleaned on Florisil. The recoveries were 102129%. Similar procedure was described in [18, 34], however, the head space solid phase microextraction (HSSPME) was applied for analytes concentration. The microwave energy was about 800950 W, temperature 115ºC. The recoveries were 84100%. Table 1. Physical chemical properties of selected pesticides No Pesticide Chemical structure Melting point, (ºC) logKOW logKOC Boiling point, (ºC) Density (20 ºC), (g/cm3) Solubilty in water (20ºC), (mg/L) Vapor pressure (25 ºC) (mPa) Cl Cl Cl Cl Cl Cl e 1,2,3,4,10,10-hexachloro-1,4,4a,5,8,8a-hexahydroexo-1,4-endo-5,8-dimethanonapthalene Cl Cl Cl Cl Cl Cl 1,2,3,4,10,10hexachloro-6,7-epoxy-1,4,4a, 5,6,7,8,8a-octahydroendo-1,4-exo-5,8-dimethanonaphthalene Cl Cl Cl Cl Cl O Cl 226-230 3,4,5,6,9,9-hexachloro-1a,2,2a,3,6,6a,7,7aoctahydro-endo-dimethanonaphthalene The detailed literature overview reveals that the most popular procedure for extraction from soil samples is liquidsolid extraction (LSE), carried out with shaking, sonication or in the presence of microwaves. Usually methanol, mixture of methanolwater (different proportions) [2, 8, 16, 17, 28, 33, 37, 46, 47, 49, 53] acetonitrile, acetonitrile water, or acetonitrile-hexane (different proportion) [1, 14, 22] or chloroform [4] are used. In some cases solid phase extraction (SPE) on octadecyl (C18), phenylsulfonyl acid (PhSO3H) or multi-walled carbon nanotubes (MWNTs) sorbents was carried out [2, 4, 33, 37, 44, 47]. The recovery was about 85 93%. Soil sonication with mixture of acetonitrile dichloromethane, acetonitrile water, ethyl acetate, water with addition of chloroform was applied by [4, 24, 25, 3133, 35, 42]. The recovery was in the range of 5095%. Microwave assisted extraction is also used for extraction from soil samples. In [48], the mixture of dichloromethane methanol as a solvent was applied, microwave power was 950 W. After filtering, solid phase microexctraction (SPME) was conducted. The recovery was 76.685.7%. For pesticides determination in environmental samples chromatographic methods are usually applied, capillary electrophoresis as well as immunenzymatic procedures [6]. For pesticides detection, the most often applied are liquid chromatography with fluorescence detection (FL), ultraviolet or diode array detection and mass detector (MS). Another technique for pesticides determination is gas chromatography with mass or nitrogen phosphorus (NPD) detector [26]. Liquid chromatography with UV detection provides LOD in the range of 0.019 g/L 0.2 g/L, 0.04 ng/g 0,05 ng/g [19, 22, 35, 47]. whereas with DAD detection: 2.0 g/L, 0.5 ng/g [5, 21, 42, 45, 52]. According to Gong [16], fluorescence detection enables to detect pesticides at 1.2 ng/g level. The lowest value of LOD (0.188 ng/g) was obtained by means of LC MS/MS by Jablonowski [20]. Gas chromatography with nitrogen phosphorus detector provides limit of detection around 0.005 mg/L [35], 1.5 ng/g 2 ng/g [3,5,9,15,32] while with mass detector 0.3 g/L, 4 ng/g 8,3 ng/g [ 9, 23, 24, 25, 33, 36]. The aim of this study was to work out the analytical procedure for the simultaneous determination of insecticides and herbicides in environmental samples by means of gas chromatography coupled with electron capture detector (GCECD). The influence of the type of extraction (UAE or MAE) as well as extraction solvents on the analytes recoveries was also presented. The obtained parameters of analysis, i.e., mass of sample, volume of solvent, extraction recovery, limit of detection and quantification were critically discussed with the literature data. On the basis of the detailed literature review, it follows that there were no trials of simultaneous determination of chloroorganic compounds and compounds with nitrogen atom(s) in soil. Taking into account the specificity of ECD detector, it was usually applied for chloroorganic insecticides determination. In the present paper, the innovative application of ECD detector for simultaneous determination of insecticides and triazine, provided limit of detection in the range of 6 ng/g 8 ng/g for insecticides and 1.5 ng/g for . METHODOLOGY Chemicals and reagents The standards for , and were provided by Supelco (Bellefonte, USA), was obtained from Reidel-de-Haen, (Seelze, Germany). All applied compounds were used without purification. Stock standards solutions were prepared by dissolving standard in n-hexane (for insecticides), was dissolved in methanol. Working standard solutions were prepared by dilution of suitable aliquots from stock solution in appropriate solvent. The oncentrations of these solutions are presented in Table 2. All solutions were stored at 4°C in the dark. Helium (99.9999%) and nitrogen (for ECD) were purchased from Linde (Germany). Acetone was bought in Z.B.P. HEMED, (Gliwice, Poland), methylene chloride was from CHEMPUR, (Piekary Sl., Poland), methanol, n-hexane and sodium sulphate (VI), anhydrous, were provided by POCH. S.A., (Gliwice, Poland). Apparatus and equipment For the pesticides extraction from soil samples a microwave oven Multiwave 3000 SOLV Anton Paar, (Graz, Austria), equipped with microwaves generator (2.45 GHz), temperature and pressure sensors IR and p/T, respectively, power 1400 W, rotator for 8 and 16 samples. Ultrasound bath POLSONIC 2, (Warsaw, Poland), frequency 40 kHz, ultrasound power 2x100 W, was used for UAE. Qualitative and quantitative analyses were preformed using Perkin-Elmer Clarus 500 gas chromatograph (GC) equipped with an electron capture detector (ECD), and a 30 m × 0.25 mm i.d. DB5MS column with a film thickness of 0.25 m. Analysis conditions The column temperature was programmed to increase from 150°C to 275°C, at 10°C/min, held for 3 min, and then from 275°C to 300°C, at 16°C/min; the temperature of injector was 250°C, temperature of detector 310°C. Investigated compounds were identified by their retention times. The quantitative analysis was performed with the use of the external standard method. An exemplary chromatogram of pesticides standard mixture is showed in Fig. 1. Fig. 1. Chromatogram of standards mixture solution, 1 , 2 , 3 , 4 ; n.d not determined Table 2. Working standards solutions concentrations [mg/mL] on six concentration levels Analyte 0.602 0.606 0.608 0.207 0.277 0.346 0.810 1.013 1.315 0.449 0.808 1.010 1.312 0.802 1.003 1.302 Level I Level II Level III Level IV Level V Level VI 1.496 1.508 1.512 0.516 Table 3. Precision of the procedure for pesticides determination Analyte 0.005 0.042 0.049 0.036 0.403 1.496 0.406 1.508 0.407 1.512 0.139 0.516 LOD [mg/mL] LOQ [mg/mL] Linearity range [mg/mL] Equation of calibration plot y = 480252 x - 19021 y = 2620071 x + 4696462 y = 3064620 x + 4100559 y = 3335272 x + 5130203 R2 0.994 0.995 0.997 0.998 Validation of pesticides determination procedure Six nonzero calibration standards for , , and , covering the concentration range given in Table 2, were prepared. The analysis was repeated six times for each concentration level. The detailed parameters of calibration curves are presented in Table 3, whereas, the plots are presented in Fig 2. Extraction procedures Ultrasound assisted extraction (UAE) Spiked soil sample (5.0 g) was placed in shakeflask, 55 mL of n-hexane was added and the mixture was sonicated for 20 min. The sonication was repeated three times. Subsequently, the sample was filtrated, solvent evaporated and the residue, prior to analysis, was dissolved in 0.5 mL of methanol (Procedure I). For the Procedure II, the conditions of extraction were the same as for Procedure I, however, methylene chloride was applied. Fig. 2. Plots of calibration curves Microwave assisted extraction (MAE) Spiked soil sample (0.5 g) was extracted with 17.5 mL of n-hexane and 7.5 mL of acetone, the temperature programmed to 120ºC at 24ºC/min and held for 20 min. Microwaves energy was 1200 W. After cooling, the extract was filtrated in the presence of sodium sulphate (VI), then evaporated to dryness. The residue was dissolved in 0.5 mL of methanol and the chromatographic analysis was conducted (Procedure III). Recovery determination To estimate the recoveries of MAE and UAE, the reference soil sample was prepared according to the following procedure. Soil was dried on filter paper for 24 h. One hundred grams of pulverized, sieved through a 0.8 mm sieve soil was poured with 125 mL of methylene chloride. Subsequently, the ultrasound assisted extraction (20 min.) was conducted. The extraction procedure was repeated three times. Then, after filtering, soil was dried till the solvent was completely removed. The extract of the methylene chloride was discarded. To evaluate the extractions efficiencies, 0.5 and 5.0 g of dried and deprived of organic matter soil were weighted out for MAE and UAE, respectively. Soil was spiked with 1.0 mL and 0.5 mL of pesticides standards solution for UAE and MAE procedure, respectively. The concentration of this solution is presented in Table 2, Level VI. After two hours the references samples were analyzed. The recovery was determined for six references samples. The comparison of recoveries of pesticides from reference soil samples are presented in Fig. 3. The highest recoveries of all investigated compounds were obtained by means of Procedure III, therefore, the detailed validation parameters of this procedure are presented in Table 4. The blank sample (without standards addition) was prepared, according to the above described Procedure III, to estimate the precision of the procedure of pesticides determination in soil samples. Limits of detection of the procedure (LOD) were calculated based on signal to noise ration S/N for blank sample, limits of quantification (LOQ) as threefold LOD. Values of LOD and LOQ are given in Table 5. Procedure I Procedure II Procedure III Fig. 3. Recoveries of pesticides from references soil samples Environmental samples Top soil samples were collected from five different locations in Poland, both agricultural and urban areas. Detailed characteristics of soil samples are given below: Agricultural area: S1 soil from wheat cultivation, S2 rye cultivation, S3 maize cultivation; urban area: S4, S5 soil from heavy polluted areas and former waste storage yard. Soil samples were collected according to standard PN-R-04031:1997. Stones and residues of plants were removed and the pesticides were extracted according to the Procedure III. The masses of the samples taken for analysis were in the range of 0.55.0 g depending of pesticides concentration. DISCUSSION On the basis of the detailed literature review, it follows that there were no trials of simultaneous determination of chloroorganic compounds and compounds with nitrogen atom(s) in soil. Taking into account the specificity of ECD detector, it was usually applied for chloroorganic insecticides determination. In the present paper, the innovative application of ECD detector for simultaneous determination of insecticides and triazine, provided limit of detection, found in the range of 12 g/mL 18 g/mL, for insecticides and 2 g/mL for . In this range the linearity responses were obtained. The acceptance criteria for the correlation coefficient, R2, of the calculated regression curves were 0.994 or higher. The detailed parameters of calibration curves are presented in Table 3, whereas, the plots are presented in Fig. 2. Recovery study In the course of experiment, according to the methodology described in Extraction procedures, the recovery of investigated compounds from soil was determined and relative standard deviation (RSD%) was computed and graphically presented in Fig. 3. Table 4. Recovery study of investigated pesticides by means of Procedure III Analyte Added [mg] 0.516 1.496 1.508 1.512 Measured [mg] 0.432 0.992 1.049 1.288 Recovery [%] 83.8 66.3 69.6 85.2 R.S.D. (n=6) 0.052 0.004 0.022 0.018 Table 5. Limits of detection and quantification of Procedure III Analyte e e e LOD [mg/mL] 0.002 0.014 0.016 0.012 LOQ [mg/mL] 0.005 0.042 0.049 0.036 R.S.D. (n=6) 0.146 0.084 0.096 0.061 CV (%) 14.59 8.43 9.56 6.08 The CV computed for six samples was 18% for and in the range of 3.35.0% for insecticides, for the Procedure I; 8.0% for and 1.32.3% for insecticides, for Procedure II. The lowest values of CV for all compounds were observed for the Procedure III, namely 5.3% for and 0.042.2% for insecticides. Such CV values indicated good precision of the method. Ultrasound assisted extraction with n-hexane as solvent gave the lowest recoveries of all compounds, for insecticides 4059% and 8% for . Moreover, this procedure was characterized by the highest values of CV. The exchange of n-hexane for methylene chloride improved the recoveries of (85.5%), (70.1 %) and (15.8%), whereas, the recovery of remained unchanged (57.8%), nevertheless still too low for quantitative analysis. According to our previous study [5], low recoveries of obtained by means of ultrasound assisted extraction is not connected with the solvent neither with ultrasound bath (the recoveries of other compounds were satisfactory). The extractions with chloroform, acetone, mixture acetone water (1:1, v/v), methanol, mixture methanolwater (1:1, v/v), buffers (pH 1.55.0) were also conducted. In all cases the recoveries did not exceed 50%, that was noticed for methanol as a solvent. The same solvents were used for shake flask extraction. In this technique recoveries were above 70%, the highest value was recorded for chloroform (97%) [3, 5]. Low recoveries of obtained by UAE were also observed by Lesueur [24]. According to our best knowledge, there is no profound explanation of this phenomenon in the literature. The highest recoveries were observed for microwave assisted extraction and were in the range of 6685% for insecticides and 84% for . The recoveries of investigated herbicide and insecticides are presented in Table 4. The obtained results indicate that satisfactory recoveries of all investigated analytes (above 60%) were achieved by means of microwave assisted extraction with the mixture of n-hexane and acetone and the detection by GCECD. Therefore, this procedure was chosen for pesticides determination in environmental samples. For the Procedure III, the precision of pesticides determination was calculated, taking into consideration the recoveries of analytes and quantitative determination (Table 5). The obtained limits of detection are in the range of 6 ng/g 8 ng/g for insecticides and 1.5 ng/g for . Analysis of real soil samples The highest recoveries of all investigated compounds were obtained by MAE extraction Procedure III, therefore this procedure was chosen for the pesticides extraction from real soil samples In soil samples (S1S3) collected in agricultural areas, was determined in all cases, at levels in the range from 30.4 to 110.7 g/g, was detected in soil from wheat and rye cultivation, in latter also was detected. Chromatogram of the soil extract (S2) is presented in Fig. 4. In soil samples from rural areas was determined in samples S4 and S5 at the concentration levels 18.7 g/g and 56.7 g/g, respectively. High concentration of determined in real soil samples is connected with intensive usage of this herbicide in the past. Fig. 4. Chromatogram of soil sample extract obtained by Procedure III, 1 , 2 , 3 CONCLUSION The presented MAEGCECD method enables to extract and determine , , and in soil samples with high recoveries, precision and limits of detections in the range of 6 ng/g 8 ng/g in the case of insecticides and 1.5 ng/g for . The application of electron capture detector enables to determine simultaneously both chloroorganic insecticides as well as herbicides with nitrogen atoms in the structure. The comparison of results obtained by different techniques sometimes is questionable, therefore, the proposed procedure may describe this issue. Microwave assisted extraction provides higher recoveries of analytes in comparison to ultrasound assisted extraction, regardless of solvent.
Archives of Environmental Protection – de Gruyter
Published: Mar 1, 2013
You can share this free article with as many people as you like with the url below! We hope you enjoy this feature!
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.