The aim of the study was to analyze and assess the possibility of using a two-stage filtration system with ceramic membranes: a 3-tube module with 1.0 kDa cut-off (1st stage) and a one-tube module with 0.45 kDa cut-off (2nd stage) for treating effluent water from a juvenile African catfish aquaculture. The study revealed that during the 1st filtration stage of the effluent water, the highest degrees of retention were obtained with respect to: suspended solids SS (rejection coefficient RI=100%), turbidity (RI=99.40%), total iron (RI=89.20%), BOD5 (RI=76.0%), nitrite nitrogen (RI=62.30%), and CODCr (RI=41.74%). The 2nd filtration stage resulted in a lower reduction degree of the tested indicators in comparison to the 1st filtration stage. At the 2nd stage, the highest values of the rejection coefficient were noted in for the total iron content (RIV=100%), CODCr (RIV=59.52%; RV=64.28%, RVI=63.49%) and turbidity (RIV and RV = 45.0%, RVI=50.0%). The obtained results indicate that ceramic membranes (with 1.0 and 0.45 kDa cut-offs) may be used in recirculation aquaculture systems as one of the stages of effluent water treatment. Introduction Fish breeding and fish farming are potential sources of surface water pollution. Effluent waters from aquaculture are characterized by a considerable percentage content of biogenic compounds originating from the leftovers of fish fodder, metabolic waste products of the fish (ammonium nitrogen, urea), as well as fertilizers used for fish pond fertilization (Rosenthal and Hilge 1992, Good et al. 2009, Davidson et al. 2013). In order to eliminate or diminish the effect of pollution generated by fish farming on surface waters, the Recirculating Aquaculture Systems (RAS) are implemented. In RAS, the pollution is eliminated by biological treatment combined with conventional separation techniques such as sedimentation, flocculation and filtration (Schneider et al. 2007, Martins et al. 2009, Martins et al. 2010, Van Rijn 2013). The membrane filtration can be used for improving treatment systems for RAS. Both polymer and ceramic membranes can be used in filtration systems (Viadero and Noblet 2002, Yonnekawa et al. 2004, Matsushita et al. 2005, Yang et al. 2006,Gemende et al. 2008, Szmukala and Szaniawska 2009, Bonislawska et al. 2010, Kabsch-Korbutowicz and Urbanowska 2010, Harvianto et al. 2013). Polymer membranes are widely available and characterized by diversified separation capacities. However, they are less resistant to the effect of chemical, thermal and biological factors in comparison to ceramic membranes. The advantages of ceramic membranes are: their lifetime is longer compared to the polymer membranes, they may be sterilized with water vapor and cleaned using strong acids and bases, they can be stored dry after rinsing, and used membranes can be reused as ceramic material (Sondhi et al. 2003). The aim of the study was to analyze and evaluate the possibility of using a serial two-stage filtration system with third-generation ceramic membranes: a 3-tube module with 1.0 kDa cut-off (1st stage) and a one-tube module with 0.45 kDa cut-off (2nd stage) for the treatment of effluent water from the aquaculture of juvenile African catfish (Clarias gariepinus Burchell, 1822) in RAS. It was assumed that at the first stage the treatment system of that kind would eliminate high-molecular substances from the effluent water, while at the second stage the reduction of substances with lower molecular masses (e.g. biogenic substances) would take place. Materials and methods The studies were conducted on a small-scale membrane installation realizing cross-flows, composed of: a 50-liter feed tank, a pump equipped with a stepless rotation adjustment system, a tubular membrane module, a flow heat exchanger, and a permeate tank, as well as thermometers and nanometers for temperature and pressure control (Fig. 1). At the 2nd filtration stage the membrane with 0.45 kDa cut-off was used. The filtration was conducted using a 1-tube module with total membrane surface of AII=0.25 m2. The transmembrane pressure equaled TMPII=0.40 MPa. The feed (NII) at the 2nd filtration stage was the permeate obtained from the 1st filtration stage (NII=PI+PII+PIII) (Fig. 2). According to methodologies recommended by Standard Methods (1998), selected physico-chemical indicators were measured in the feed, as well as in the permeate (P) and the retentate (Re) collected at hourly intervals. Biological oxygen demand (BOD5, mgO2 dm) was determined by a direct method after five day incubation of the samples with no light access at the constant temperature of 20°C. Chemical oxygen demand (CODCr, mgO2 dm) was determined by the dichromate method. Suspended solids (SS, mg dm) were determined by weighing. Nitrite nitrogen (N-NO2-, mgN dm) was assayed with sulphanyl acid (=543 nm). Nitrate nitrogen (N-NO3-, mgN dm) was determined as nitrite nitrogen after the reduction on a Cu-Cd column. Ammonium nitrogen (N-NH4+, mgN dm) was assayed with indophenol blue (=630 nm). Total inorganic nitrogen (TIN, mgN dm) was calculated as the sum of nitrite, nitrate, and ammonium nitrogen contents. Total reactive phosphorus (TRP, mgP dm) was assayed using the molybdenate technique with ascorbic acid as a reducer (=882 nm). Total phosphorus (TP, mgP dm) was determined after mineralization with potassium hypersulphate and assayed as TRP. Total iron (Fe, mg dm) was determined by phenanthroline (=510 nm). The applied calorimetric methods used a spectrophotometer UV-VIS Spectroquant Pharo 300 manufactured by Merck, Germany. Conductivity was measured with a conductivity meter manufactured by Elmetron CC-101, Poland. Turbidity was measured with a turbidimeter manufactured by Eutech Instruments TN-100, Singapore. The water feeding the recirculation system of the aquaculture from which samples were collected for the membrane filtration studies was also tested with respect to its physico-chemical parameters. After conducting the water purification process, the degree of pollution reduction was measured by calculating the rejection coefficient (RI, RII, RIII). It was calculated for the respective indicators on the basis of analyzing their concentrations in the permeate (CPI, CPII) and the feed (CN) according to the formula (1). R=(1-CP/CN)×100% (1) Fig. 1. Small-scale experimental rig: 1 feed tank; 2 pump; 3 membrane module; 4 radiator; N- feed water; R retentate; P permeate; M manometer Commercial tubular membranes made of Al2O3/TiO2/ZrO2 were used. A detailed characteristics of the membranes is given in Table 1. Table 1. Characteristics of two kinds membranes used in the research Cut-off (kDa) Parameters Number of channels Hydraulic diameter of channel (mm) Membrane diameter (mm) Membrane surface (m2) Membrane length (mm) 1.0 23 3.5 25 0.35 1178 0.45 19 3.5 25 0.25 1178 The experimental research was conducted in the two-stage membrane filtration system according to the scheme shown in Figure 2. The filtration process at each stage was conducted in three cycles (duration of an individual cycle = 1 h). Between the cycles the membrane was cleaned with distilled water (without returning). Tests were conducted in an open system (i.e. the permeate was reclaimed). The filtration process at both stages was conducted at the constant temperature of 20.0°C±1 and at the fixed linear velocity of the feed equal to u = 4 ms-1. At the first filtration stage the membrane with 1.0 kDa cut-off was used. The filtration was conducted using a 3-tube module with total membrane surface of AI=1.05 m2. The transmembrane pressure equaled TMPI=0.25 MPa. The feed (NI) at the 1st filtration stage was the effluent water from intense fish farming. Volumetric of the permeate flux (JV, m3/m2s) was calculated and the relative membrane permeability was expressed as the JV/J0 ratio (where JV = permeate flux for the treated water at the 1st and 2nd filtration stage, J0 = permeate flux for distilled water). Results The effluent water (EW) from the juvenile African catfish aquaculture was characterized by heightened concentrations of water quality indicators, mainly those important for the life of fish, i.e. BOD5, CODCr, SS, TIN, and TP. Concentrations of those indicators, in comparison to concentrations found in the feed water, were higher by 594%, 2414%, 3000%, 6670% and 343%, respectively (Table 2). Table 2 contains also the requirements of the Polish Minister of Environment's Regulation of 24 July 2006 on wastewater discharge into natural environment. Comparing the values of selected physico-chemical indicators noted in the effluent water with the above mentioned requirements, it was found that substance accretion in the effluent water exceeded acceptable values specified under the Regulation. The values were especially high for such indicators as TIN, CODCr, TP and SS, exceeding the norms 25, 21, 9 and 5 times, respectively (Table 2). The effluent waters, considerably polluted with organic matter and biogenic elements, were used in the treatment process applying membrane filtration; they constituted the feed (NI) at the 1st filtration stage. Results of permeate quality testing obtained at the 1st filtration stage are compiled in Table 3. The study revealed that already after the first hour of filtration the values of the tested physico-chemical indicators were reduced. The highest degree of retention was obtained for the total suspended solids, turbidity, total iron, BOD5, nitrite nitrogen and CODCr. The values of the rejection coefficient (RI) for those indicators equaled: 100.0%, 99.4%, 89.2%, 76.0%, 62.3% and 41.74%, respectively (Tab. 3). The following permeate quality measurements were conducted after two and three hours of filtration; the values of the tested physico-chemical indicators showed a decreasing tendency and thus the degree of rejection of the pollution on the membrane was increasing. Total reduction was noted for the total suspended solids and the total iron content. For the total suspended solids, 100% rejection was already obtained after the first hour of filtration, whereas for the total iron content the same rejection level was obtained after two hours of filtration. After three hours of filtration a high level of rejection was noted for CODCr, BOD5, nitrite nitrogen and turbidity, with RIII equal to: 76.81%, 96.1%, 64.18%, and 99.8%, respectively. The values of the remaining indicators in the retentates decreased only slightly and the rejection coefficient values ranged from 0.17% (ammonium nitrogen) to 11.67% (total phosphorus) (Table 3). The results of testing the quality of the permeate obtained at the 2nd filtration stage are given in Table 4. A decreasing tendency was noted with regard to the values of the tested physico-chemical parameters during the filtration process. However, the rejection coefficient values of the studied indicators obtained at that stage were lower than those obtained Table 2. Characteristics of selected quality indicators of feed water (FW) and effluent water (EW) in the juvenile African catfish aquaculture, substance accretion () and substance accretion norms according to the Polish Minister of Environment's Regulation of 24 July 2006 Water quality index BOD5 CODCr SS TIN TP Feed water FW 0.86 6.4 0.0 0.388 0.389 Effluent water EW 5.11 154.5 30.0 25.88 1.336 Substance accretion () (EWFW) 4.25 148.1 30.0 25.50 0.947 Requirements Regulation... 2006 3.0 7.0 6.0 1.0 0.1 Table 3. Values of the tested physico-chemical indicators at the 1st filtration stage in the feed NI, and measured after 1, 2 and 3 hours of filtration in the permeates (PI, PII, PIII) and retentates (ReI, ReII, ReIII). RI, RII,RIII rejection coefficients Water quality index BOD5 (mgO2 dm) CODCr (mgO2 dm ) NI 5.11 154.51 30 50.65 3151 0.774 0.120 3.270 25.88 3.148 1.336 2.313 PI 1.22 90.20 0 0.30 3102 0.773 0.045 3.246 25.39 3.091 1.255 0.251 RI [%] 76.02 41.74 100 99.40 1.55 0.17 62.68 1.63 1.91 1.82 6.04 89.17 PII 1.26 88.16 0 0.18 3091 0.772 0.045 3.188 24.09 3.000 1.253 0.00 RII [%] 75.36 42.94 100 99.64 1.90 0.28 62.68 3.38 6.95 4.71 6.18 100 PIII 0.20 35.82 0 0.10 2841 0.753 0.043 3.054 24.05 2.988 1.180 0.00 RIII [%] 96.10 76.81 100 99.80 9.86 2.68 64.18 7.46 7.10 5.09 11.67 100 ReI 7.65 330.37 84 300.00 3190 0.988 0.235 3.370 25.57 3.912 3.527 5.098 ReII 8.11 227.82 100 312.00 3289 0.864 0.276 4.074 25.38 3.845 3.586 5.428 ReIII 10.10 223.86 118 285.50 3622 0.858 0.334 4.404 25.39 3.865 3.768 5.544 SS (mg dm) Turbidity (NTU) Conductivity (S cm-1) N-NH4+ (mgN dm) N-NO2- (mgN dm) N-NO3- (mgN dm) TIN (mgN dm) TRP (mgP dm) TP (mgP dm) Total iron (mgFe dm) Membrane cleaning, conducted hourly during the experimental study, resulted in increasing the efficiency of Jv at the 1st and the 2nd filtration stage (Fig. 2). Each time, the membrane cleaning lasted for 30 min and was performed after 60, 150 and 240 minutes of the filtration process. Initially, for the 3-tube model applied at the 1st filtration stage, the Jv dramatically dropped and after ca. 1h it was equal to less than 50% of the original efficiency. Membrane cleaning again increased the efficiency level, with average Jv values growing from 2.7 to 3.65 (m3/m2s10-5). At the 2nd filtration stage the efficiency was much lower and remained at roughly the same level. The cleaning process at that stage also increased the Jv values, on average from 1.15 to 1.66 (m3/ m2s10-5) (Fig. 3). at the 1st filtration stage. The highest rejection coefficient values at the respective points of time in the course of the filtration process were noted for the total iron (RIV=100%), CODCr (RIV=59.52%; RV=64.28%, RVI=63.49%) and turbidity (RIV, RV=45%, RVI=50.0%). For the remaining indicators concentration reductions at the following points of time during the filtration were comparatively low and rejection coefficients ranged from RVI=0.06% (ammonium nitrogen) to RVI=21.33% (nitrate nitrogen) (Table 4.). During the filtration process, at both filtration stages, it was noted that in the concentrated retentate solution (ReI-ReVI) the values of the respective physico-chemical indicators increased, and were especially high for SS, BOD5, CODCr and turbidity (Tabs 3 and 4). Table 4. Values of the tested physico-chemical indicators at the 2nd filtration stage in the feed NII, and measured after 1, 2 and 3 hours of filtration in the permeates (PIV, PV, PVI) and retentates (ReIV, ReV, ReVI). RIV, RV,RVI rejection coefficients Water quality index BOD5 (mgO2 dm) CODCr (mgO2 dm) Turbidity (NTU) Conductivity (S cm-1) N-NH4 (mgN dm ) + NII 1.74 58.47 0.20 2688 0.719 0.039 3.198 22.45 1.934 1.248 PIV 1.39 23.66 0.11 2600 0.718 0.038 2.973 21.62 1.905 1.229 0.0 RIV[%] 20.13 59.52 45.00 1.51 0.12 1.16 7.04 11.44 1.48 1.47 100 PV 1.30 20.88 0.11 2600 0.718 0.037 2.752 18.88 1.910 1.202 0.0 RV[%] 25.54 64.28 45.00 1.51 0.12 1.74 13.96 11.44 1.22 3.68 100 PVI 1.32 21.34 0.10 2412 0.718 0.037 2.516 19.80 1.923 1.211 0.0 RVI[%] 24.25 63.49 50.00 8.64 0.06 2.32 21.33 11.80 0.56 2.94 100 ReIV 2.30 87.70 1.11 3036 0.753 0.039 3.238 23.87 1.996 1.253 0.038 ReV 2.88 81.20 0.92 3276 0.760 0.039 3.800 23.73 1.996 1.278 0.042 ReVI 3.29 171.22 0.91 3252 0.771 0.039 4.023 23.99 2.000 1.408 0.046 N-NO2- (mgN dm) N-NO3 (mgN dm ) TIN (mgN dm) TRP (mgP dm ) TP (mgP dm) Total iron (mgFe dm ) 1st stage 1.0 kDa NI PI ReI 2nd stage 0.45 kDa NII PIV ReIV NI PII PV NII ReII ReV NI PIII PVI NII ReIII ReVI Fig. 2. A block diagram of the conducted experiment featuring the 1st and 2nd filtration stages. NI feed tank I (effluent water from RAS); NII feed tank II (mixed permeates PI, PII, PIII from the 1st filtration stage); ReI-VI retentates 1 stage 1.0 kDa, TMP=0.25 MPa 2 stage 0.45 kDa TMP=0.40 MPa Jv (m3/ m2 *s *10-5) Time (min) Fig. 3. The relationship between the permeate flux Jv, and th time and TMP in the two-stage ultrafiltration of effluent water from the juvenile catfish aquaculture Discussion The effluent water from the juvenile African catfish aquaculture was strongly polluted with organic matter and biogenic substances and did not meet the requirements outlined in the Polish Minister of Environment's Regulation of 24 July 2006 on conditions of discharging wastewater into natural waters or into the ground, and on the substances especially harmful to aquatic environment. Therefore, that type of effluent water should undergo an efficient treatment process. In spite of the low water quality in the aquaculture system, the growth and development of the fish was normal. The fish species in question is characterized by a high tolerance for unfavorable environmental conditions (Viveen et al. 1985) Since the 1990s, the African catfish has been a popular species in Polish fish farms. Its farming is mainly conducted in closed-circulation systems. The fish is thermophilous and omnivorous, and reaches sexual maturity at the age of 610 months. A special characteristics of the species is its ability to breathe atmospheric oxygen if it lives in strongly polluted waters with low oxygen content (Viveen et al. 1985). The meat of the catfish is highly valued for its flavor (similar to veal); it has a low fat content and a high total protein content (Nyina-Wamwiza et al. 2007). As the species is not very sensitive to oxygen deficits and pollution, it is possible to use water of inferior quality in its farming. At the same time, breeding and farming of the African catfish are very intensive and generate strongly polluted wastewater. This fact, in light of striving for sustainable aquaculture which aims to maintain natural resources in the best possible condition while producing food, implies the necessity to develop and introduce in practice such farming techniques that will minimize its negative impact on the environment. One of possible solutions is the implementation of RAS, using various methods for effluent water treatment (Martins et al. 2010). Recirculation systems, commonly applied for fish breeding and farming, are based on mechanical (filters, sedimentation tanks), biological (trickling filters), or chemical water purification and finally, its disinfection (UV radiation, ozonization) (Yang et al. 2006, Singer et al. 2008, Van Rijn 2013). The studies on applying membrane separation techniques in treatment systems are a recent trend (Viadero and Noblet 2002, Gemende et al. 2008, Harvianto et al. 2013, Yang et al. 2006). Gemende et al. (2008) applied capillary polymer membranes in recirculation systems in order to minimize water consumption while maintaining safe concentrations of nitrogen associations and suspensions. The applied membranes totally eliminated the suspended solids and decreased the biomass content to the level enabling further processing by fermentation. Viadero and Noblet (2002) also applied polymer filtration membranes in RAS and obtained a high retention of BOD5 and CODCr, at the level of 71% and 67% respectively. Furthermore, Bonislawska et al. (2010) tested the possibility of applying modern third-generation ceramic membranes in the one-stage process of eliminating pollution from the water discharged by fish hatcheries, pointing to the possibility of its recirculation. Another study tested a two-stage process of treating water from a fish hatchery (3-tube module at the 1st stage; 1-tube module at the 2nd stage) using ceramic membranes with 1.0 kDa cut-off. That system allowed for eliminating from the water 100% of total suspended solids, 93% of CODCr and 73% of BOD5 Szaniawska et al. 2011. Similarly, Fu et al. (1995) and Yang et al. (2006) obtained high rejection coefficient values for turbidity: 84.089.2% and 86.5% respectively. Furthermore, Yang et al. (2006) applied a hybrid system (combining polymer microfiltration membranes with chemical precipitation) and obtained even better results (98.099.9%). Orecki and Tomaszewska (2004), purifying lake water with an NF-270 nanofiltration polymer membrane obtained the retention level of 85.9% for CODCr. The present studies allowed for obtaining a similar rejection level of the tested indicators already at the 1st filtration stage. A high efficiency of the applied ceramic membranes was also noted for iron elimination. The 2nd An important phenomenon in membrane separation processes is the phenomenon of fouling connected with gradual blocking of membrane pores (irreversible fouling) and the development of a filter on its surface (reversible fouling). The phenomenon acts as an additional filter, contributing to the occurrence of hydraulic resistance and decreasing the volume of permeate flux over time (Mohammad et al. 2012, Luo and Wan 2013). The permeate flow decreases quickly during the first 1015 minutes of filtration and then achieves a quasi-steady state value after ca. 3040 minutes (Viadero and Noblet 2002). A similar decrease of the permeate flow was also noted in the present study at the 1st filtration stage. However, at the 2nd filtration stage the permeate flow decreased only slightly over time. The results indicated that at the latter stage fouling was lower than at the 1st stage. Cyclic membrane cleaning with deionized water increased membrane efficiency, but did not make it as efficient as at the beginning of the experiment. The results of the studies showed that a drop in the membrane efficiency level at both filtration stages was caused by the phenomena of reversible and irreversible fouling, typical for membrane separation processes. At the same time, at the 1st filtration stage each following membrane cleaning cycle restored a lower level of membrane efficiency, which pointed to the increasing role of irreversible fouling in the reduction of the permeate flux volume. Membrane blockage is one of the most serious exploitation problems connected with the processes of micro- and ultrafiltration. Even though ceramic membranes are strongly hydrophilous, they are blocked mainly by organic substances present in water (Verweij 2003). The effluent water used in the present study as the feed at the 1st filtration stage was rich in organic matter (both dissolved and in the total solution), which should be considered as a major factor contributing to the occurrence of fouling. The feed at the 2nd filtration stage was characterized by lower CODCr and BOD5 concentrations as well as the absence of total suspended solids. Thus, the fouling phenomenon was less intense and the efficiency of the permeate flux volume remained roughly the same over time. filtration stage resulted in a further drop in the values of the analyzed physico-chemical indicators, but to a lesser extent. The differences are explicable by differences in qualitative composition of the feed. At the 1st stage, effluent water from the juvenile African sharptooth catfish aquaculture was the feed (NI), whereas at the 2nd stage the permeate obtained after the 1st stage filtration was the feed (NII=PI+PII+PIII). The differences in qualitative composition of the feed determined also the phenomenon of membrane fouling, which shall be discussed below. Similar differences in the rejection levels in the two-stage filtration process were also noted by Szmukala and Szaniawska (2009), who compared the performance of ceramic membranes with different cut-offs in two-stage systems. In their study, the 1st stage involved the filtration through a membrane with the 1.0 kDa cut-off, and rejection coefficients for BOD5 and CODCr ranged between 8992% and 4533% respectively. At the 2nd filtration stage the authors tested a membrane with the 3.0 kDa cut-off, and rejection coefficients for BOD5 and CODCr ranged between 4968% and 2435% respectively. Furthermore, low rejection coefficients for NNH4+, NNO3-, NNO2-, TIN, TRP, and TP should be pointed out. Similar results were obtained e.g. by Yang et al. (2006), Bonislawska et al. (2010) and Szaniawska et al. (2011). In the present study, among that group of indicators, the highest rejection was noted for nitrate nitrogen (at the 1st filtration stage the rejection coefficient equaled 62.364.18%). The results were concurrent with those obtained by Van der Bruggena et al. (2001, 2002), who noted a wide range of nitrate elimination: from 16.0 to 76.0%, depending on the type of applied nanofiltration membrane. For the ammonium nitrogen, the rejection level was up to 21%. The present result was similar to that obtained by Waniek (2006), i.e. 24%, however, in that author's study polymer membranes were used. Efficiency of the process of membrane separation depends on the molecular mass of the filtered substance. For instance, Kabsch-Korbutowicz et al. (2009) studied the efficiency of separation for substances with various molecular masses on a ceramic membrane with 50.0 kDa cut-off. They observed that regardless of the transmembrane pressure, 95100% of substances with greater molecular mass were retained, while the efficiency of eliminating substances with molecular mass within the range 327466 Da was lower and depended on the transmembrane pressure. They also noted that as the pressure increased, the efficiency of separation deteriorated for substances with low molecular mass; it may be explained by the fact that a pressure increase causes an increase in membrane permeability and an increasing number of small molecules diffuse across the membrane. Similar relationships were noted in the present study. A membrane with a smaller cut-off (0.45 kDa) and a higher transmembrane pressure were applied at the 2nd filtration stage than at the 1st filtration stage. Under such filtration conditions, the rejection coefficient for analyzed physicochemical indicators was lower at the 2nd filtration stage than at the 1st filtration stage. The results pointed out that at the 2nd filtration stage the substances with lower molecular masses were more likely to diffuse across the membrane (biogenic substance concentrations were not subject to considerable reductions). Conclusions The results of the conducted studies using ceramic membranes (with 1.0 and 0.45 kDa cut-offs) showed that such membranes may be used in recirculation systems of aquacultures as one of the stages of effluent water purification. The studied membrane system proved excellent for eliminating organic matter from the effluent water. However, due to a comparatively low reduction of dissolved nitrogen and phosphorus forms, such a membrane system may function as an element of a hybrid system in which the respective stages of effluent water purification contribute to decreasing biogenic element concentrations. Another element of such a hybrid system might be an aquaponics system, in which plants intensely absorb N and P. Developing a hybrid system composed of a pressure membrane separation system and aquaponics may provide an attractive alternative for classical, complicated purification systems that are presently applied in intensive aquaculture.
Archives of Environmental Protection – de Gruyter
Published: Jun 1, 2016
You can share this free article with as many people as you like with the url below! We hope you enjoy this feature!
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.