Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm

Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm A person who has severe hand tremor will have difficulty in doing specific tasks such as eating, combing or holding any objects. Currently, there is no medication that can cure the tremor. Thus, this study proposes the active tremor control, in which an intelligent controller is applied to suppress the hand tremor. The main objective is to optimise the proportional-integral (PI) controller using genetic algorithm (GA). A linear voice coil actuator (LVCA) is applied onto a four degree of freedom (4-DOF) human hand model represented in state space. The findings of the study demonstrate that the PI controller optimised by GA gives excellent performance in reducing the tremor error. Based on the frequency evaluation, the PI controller performance was roughly around 84% in reducing the peak of simulated hand tremor. The outcomes provide an important contribution towards achieving novel methods in suppressing hand tremor model by means of intelligent control. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png International Journal of Advanced Mechatronic Systems Inderscience Publishers

Loading next page...
 
/lp/inderscience-publishers/tremor-suppression-for-4-dofs-biodynamic-hand-model-using-genetic-qgVjW3xsgQ

References

References for this paper are not available at this time. We will be adding them shortly, thank you for your patience.

Publisher
Inderscience Publishers
Copyright
Copyright © Inderscience Enterprises Ltd
ISSN
1756-8412
eISSN
1756-8420
DOI
10.1504/IJAMECHS.2017.086207
Publisher site
See Article on Publisher Site

Abstract

A person who has severe hand tremor will have difficulty in doing specific tasks such as eating, combing or holding any objects. Currently, there is no medication that can cure the tremor. Thus, this study proposes the active tremor control, in which an intelligent controller is applied to suppress the hand tremor. The main objective is to optimise the proportional-integral (PI) controller using genetic algorithm (GA). A linear voice coil actuator (LVCA) is applied onto a four degree of freedom (4-DOF) human hand model represented in state space. The findings of the study demonstrate that the PI controller optimised by GA gives excellent performance in reducing the tremor error. Based on the frequency evaluation, the PI controller performance was roughly around 84% in reducing the peak of simulated hand tremor. The outcomes provide an important contribution towards achieving novel methods in suppressing hand tremor model by means of intelligent control.

Journal

International Journal of Advanced Mechatronic SystemsInderscience Publishers

Published: Jan 1, 2017

There are no references for this article.