Get 20M+ Full-Text Papers For Less Than $1.50/day. Start a 14-Day Trial for You or Your Team.

Learn More →

Determination of trace elements in mineral water by MIP OES using the Marin-5 nebulization system

Determination of trace elements in mineral water by MIP OES using the Marin-5 nebulization system In this study, three analytical procedures for the determination of inorganic constituents in mineral water were performed. To increase sensitivity, the Marin-5 nebulization system was coupled to ICP OES and MIP OES for Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Pb determination in mineral water and, thus, meet the requirements of Brazilian legislation. The accuracy of MIP OES and ICP OES measurements was evaluated using the certified water reference material (NIST 1643e). Recovery rates obtained ranged from 83% to 117%. The use of the Marin-5 nebulization system provided an increase in sensitivity, leading to limits of detection that were up to 6 times lower for ICP OES and 3 times lower for MIP OES. In addition, it made it possible for both techniques to meet the maximum limits allowed by Brazilian legislation for Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Pb in mineral water. Most water samples had concentrations within limits established by Brazilian legislation for mineral water, except for Al and Pb, which in four samples exceeded the maximum allowed limits. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Journal of Analytical Atomic Spectroscopy Royal Society of Chemistry

Determination of trace elements in mineral water by MIP OES using the Marin-5 nebulization system

Loading next page...
 
/lp/royal-society-of-chemistry/determination-of-trace-elements-in-mineral-water-by-mip-oes-using-the-SXEgzoNrQp

References (12)

Publisher
Royal Society of Chemistry
Copyright
This journal is © The Royal Society of Chemistry
ISSN
0267-9477
eISSN
1364-5544
DOI
10.1039/d3ja00068k
Publisher site
See Article on Publisher Site

Abstract

In this study, three analytical procedures for the determination of inorganic constituents in mineral water were performed. To increase sensitivity, the Marin-5 nebulization system was coupled to ICP OES and MIP OES for Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Pb determination in mineral water and, thus, meet the requirements of Brazilian legislation. The accuracy of MIP OES and ICP OES measurements was evaluated using the certified water reference material (NIST 1643e). Recovery rates obtained ranged from 83% to 117%. The use of the Marin-5 nebulization system provided an increase in sensitivity, leading to limits of detection that were up to 6 times lower for ICP OES and 3 times lower for MIP OES. In addition, it made it possible for both techniques to meet the maximum limits allowed by Brazilian legislation for Al, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, and Pb in mineral water. Most water samples had concentrations within limits established by Brazilian legislation for mineral water, except for Al and Pb, which in four samples exceeded the maximum allowed limits.

Journal

Journal of Analytical Atomic SpectroscopyRoyal Society of Chemistry

Published: Apr 19, 2023

There are no references for this article.