Access the full text.
Sign up today, get DeepDyve free for 14 days.
S. Punj, J. Singh, K. Singh (2021)
Ceramic biomaterials: Properties, state of the art and future prospectivesCeramics International
M. Resano, F. Vanhaecke, M. Loos-Vollebregt (2008)
Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry—a critical review with focus on solid sampling and slurry analysisJournal of Analytical Atomic Spectrometry, 23
Xiang Guo, Min-zhao Xue, Fei Chen, Q. Guo, Xin Zhou, Han Lin, Yu Chen (2021)
Local delivery and controlled release of miR-34a loaded in hydroxyapatite/mesoporous organosilica nanoparticles composite-coated implant wire to accelerate bone fracture healing.Biomaterials, 280
Wilian Wohlmann, V. Neves, Graciela Heidrich, Jussiane Silva, A. Costa, J. Paniz, V. Dressler (2018)
Development of an electrothermal vaporizer for direct mercury determination in soil by inductively-coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy
Uwe and, V. Krivan (1999)
Multielement Analysis of Graphite and Silicon Carbide by Inductively Coupled Plasma Atomic Emission Spectrometry Using Solid Sampling and Electrothermal VaporizationAnalytical Chemistry, 71
W. Harun, R. Asri, J. Alias, Farah Zulkifli, K. Kadirgama, S. Ghani, J. Shariffuddin (2018)
A comprehensive review of hydroxyapatite-based coatings adhesion on metallic biomaterialsCeramics International, 44
F. Antes, Eduardo Dullius, A. Costa, R.F. Molz, J. Paniz, E. Flores, V. Dressler (2013)
Development of a vaporization system for direct determination of chlorine in petroleum coke by ICP-MSMicrochemical Journal, 109
A. Martín‐Esteban, B. Slowikowski (2003)
Electrothermal Vaporization — Inductively Coupled Plasma–Mass Spectrometry (ETV-ICP-MS): A Valuable Tool for Direct Multielement Determination in Solid SamplesCritical Reviews in Analytical Chemistry, 33
Jussiane Silva, Lisarb Diehl, R. Picoloto, E. Flores, M. Mesko, J. Barin, F. Duarte (2020)
A solid sampling approach for direct determination of Cl and S in flour by an elemental analyzer.Food chemistry
P. Rivaro, C. Ianni, F. Soggia, R. Frache (2007)
Mercury speciation in environmental samples by cold vapour atomic absorption spectrometry with in situ preconcentration on a gold trapMicrochimica Acta, 158
Gurdev Singh, S. Soundarapandian (2018)
Effect of freezing conditions on β-Tricalcium Phosphate /Camphene scaffold with micro sized particles fabricated by freeze casting.Journal of the mechanical behavior of biomedical materials, 79
Rita Brigato, Liovando Costa, M. Costa, N. Assis, C. Kubo (2009)
Mercury, Copper, and Zinc Concentrations in Extracted Human TeethArchives of Environmental & Occupational Health, 64
L. Hench (1991)
Bioceramics: From Concept to ClinicJournal of the American Ceramic Society, 74
Jussiane Silva, Alessandra Henn, V. Dressler, P. Mello, E. Flores (2018)
Feasibility of Rare Earth Element Determination in Low Concentration in Crude Oil: Direct Sampling Electrothermal Vaporization-Inductively Coupled Plasma Mass Spectrometry.Analytical chemistry, 90 11
L. Jarup (2003)
Hazards of heavy metal contamination.British Medical Bulletin, 68
M. Aramendía, M. Resano, F. Vanhaecke (2009)
Electrothermal vaporization-inductively coupled plasma-mass spectrometry: A versatile tool for tackling challenging samples - A critical review.Analytica chimica acta, 648 1
B. Holzapfel, J. Reichert, J. Schantz, U. Gbureck, L. Rackwitz, U. Nöth, F. Jakob, M. Rudert, J. Groll, D. Hutmacher (2013)
How smart do biomaterials need to be? A translational science and clinical point of view.Advanced drug delivery reviews, 65 4
J. Pereira, C. Knorr, L. Pereira, D. Moraes, J. Paniz, E. Flores, G. Knapp (2011)
Evaluation of sample preparation methods for polymer digestion and trace elements determination by ICPMS and ICPOESJournal of Analytical Atomic Spectrometry, 26
Maria Silva, A. Paim, M. Pimentel, M. Cervera, M. Guardia (2010)
Determination of mercury in rice by cold vapor atomic fluorescence spectrometry after microwave-assisted digestion.Analytica chimica acta, 667 1-2
L. Pereira, M. Pedrotti, Tatiane Miceli, J. Pereira, E. Flores (2016)
Determination of elemental impurities in poly(vinyl chloride) by inductively coupled plasma optical emission spectrometry.Talanta, 152
L. Currie (1995)
Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995)Pure and Applied Chemistry, 67
D. Pozebon, V. Dressler, J. Becker, A. Matusch, M. Zoriy, J. Becker (2008)
Biomonitoring of essential and toxic elements in small biological tissues by ICP-MSJournal of Analytical Atomic Spectrometry, 23
J. Naozuka, C. Nomura (2011)
Total determination and direct chemical speciation of 'HG' in fish by solid sampling GF AASJournal of Analytical Atomic Spectrometry, 26
D. Moraes, J. Pereira, Liange Diehl, M. Mesko, V. Dressler, J. Paniz, G. Knapp, E. Flores (2010)
Evaluation of sample preparation methods for elastomer digestion for further halogens determinationAnalytical and Bioanalytical Chemistry, 397
A direct solid sampling method was developed for determining mercury in bioresorbable calcium phosphate-based materials by electrothermal vaporization (ETV) coupled to an inductively coupled plasma mass spectrometry (ICP-MS) instrument. The ETV system is based on fast sample heating using a halogen lamp enclosed in a glass chamber. The heating program comprises only a vaporization step (10 s) followed by a cooling step (120 s) when a solid sample was analyzed. An additional step of 20 s at 80 C was necessary when aqueous solutions were used for calibration. Mercury was vaporized at a relatively low temperature (650 C) without co-vaporizing the main matrix (more than 95% of the matrix remains in the lamp dimpled cavity). External calibration with aqueous reference solutions deposited on the sample residue was used for Hg quantification. The accuracy of the proposed method was evaluated by certified reference material analysis (MESS-3) and by pneumatic nebulization ICP-MS (NEB-ICP-MS), and no statistical difference was observed between the results. Relatively high masses (up to 10 mg) can be analyzed without interferences. The limit of quantification (0.2 ng g1) by ETV-ICP-MS was lower than that by NEB-ICP-MS (60 ng g1), the precision was better than 15% and the sample throughput was 20 per hour. Therefore, the proposed low-cost ETV system is attractive for determining Hg at the ultra-trace level in biomaterials and can be used for routine analyses.
Journal of Analytical Atomic Spectroscopy – Royal Society of Chemistry
Published: Apr 4, 2023
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.