Access the full text.
Sign up today, get DeepDyve free for 14 days.
Wei Chen, Liu-Xin Liu, Hao‐Bin Zhang, Zhongzhen Yu (2021)
Kirigami-Inspired Highly Stretchable, Conductive, and Hierarchical Ti3C2Tx MXene Films for Efficient Electromagnetic Interference Shielding and Pressure Sensing.ACS nano
Yang-yang Shen, Wenke Yang, Fudong Hu, Xuwei Zheng, Yanjun Zheng, Hu Liu, Hassan Algadi, Kui Chen (2022)
Ultrasensitive wearable strain sensor for promising application in cardiac rehabilitationAdvanced Composites and Hybrid Materials, 6
Ziyu Zhang, Yehao Zhao, Zihao Li, Lujie Zhang, Zixuan Liu, Zhenkun Long, Yunjia Li, Yao Liu, R. Fan, Kai Sun, Zidong Zhang (2021)
Synthesis of carbon/SiO2 core-sheath nanofibers with Co-Fe nanoparticles embedded in via electrospinning for high-performance microwave absorptionAdvanced Composites and Hybrid Materials, 5
Jianqiang Wang, Haofei Guo, Xiaonan Shi, Zhikan Yao, Weihua Qing, Fu Liu, C. Tang (2019)
Fast polydopamine coating on reverse osmosis membrane: Process investigation and membrane performance study.Journal of colloid and interface science, 535
Guanjun Zhu, Penggang Ren, Jin Wang, Qian Duan, Fang Ren, W. Xia, D. Yan (2020)
Highly Sensitive and Broad-range Pressure Sensor based on Polyurethane Meso-dome Arrays Embedded with Silver Nanowires.ACS applied materials & interfaces
Lin L. (2021)
419Chem. Eng. J.
Wang S. (2020)
31Adv. Funct. Mater.
B. Xu, Qihan Liu, Z. Suo, R. Hayward (2016)
Reversible Electrochemically Triggered Delamination Blistering of Hydrogel Films on Micropatterned ElectrodesAdvanced Functional Materials, 26
Dianbo Zhang, Minyue Zhang, Jingwen Wang, Hongling Sun, Hu Liu, Liwei Mi, Chuntai Liu, Changyu Shen (2022)
Impedance response behavior and mechanism study of axon-like ionic conductive cellulose-based hydrogel strain sensorAdvanced Composites and Hybrid Materials, 5
Xu M. (2018)
5264Nanoscale, 10
Liu Y. (2021)
30ACS Appl. Mater. Interfaces, 13
Wang Y. (2018)
8160J. Mater. Chem. C, 6
Jiang D. (2019)
1900074Polym. Rev., 304
Wen N. (2020)
25499J. Mater. Chem. A, 8
Wang Z. (2022)
32Adv. Funct. Mater.
Ping Wang, T. Song, H. Abo-Dief, Jie Song, Abdullah Alanazi, Bingyu Fan, Mina Huang, Zhiping Lin, A. Altalhi, Shangfen Gao, Liyuan Yang, Jin Liu, S. Feng, T. Cao (2022)
Effect of carbon nanotubes on the interface evolution and dielectric properties of polylactic acid/ethylene–vinyl acetate copolymer nanocompositesAdvanced Composites and Hybrid Materials, 5
T. Trung, N. Lee (2016)
Flexible and Stretchable Physical Sensor Integrated Platforms for Wearable Human‐Activity Monitoringand Personal HealthcareAdvanced Materials, 28
Yang Z. H. (2021)
11J. Mater. Chem. C, 8
Q. Zheng, Jeng-hun Lee, Xi Shen, Xiaodong Chen, Jang‐Kyo Kim (2020)
Graphene-based wearable piezoresistive physical sensorsMaterials Today, 36
Xiaotong Liu, Zijian Wu, D. Jiang, N. Guo, Ye Wang, Tao Ding, L. Weng (2022)
A highly stretchable, sensing durability, transparent, and environmentally stable ion conducting hydrogel strain sensor built by interpenetrating Ca2+-SA and glycerol-PVA double physically cross-linked networksAdvanced Composites and Hybrid Materials, 5
X. Chang, Liangren Chen, Jianwen Chen, Yutian Zhu, Zhanhu Guo (2021)
Advances in transparent and stretchable strain sensorsAdvanced Composites and Hybrid Materials, 4
Wang X. (2020)
392Chem. Eng. J.
Wang X. (2021)
64Nanomicro Lett., 13
Mingshuai Fan, Lu Wu, Yunping Hu, Meijie Qu, Shuaitao Yang, P. Tang, L. Pan, Hai Wang, Y. Bin (2021)
A highly stretchable natural rubber/buckypaper/natural rubber (NR/N-BP/NR) sandwich strain sensor with ultrahigh sensitivityAdvanced Composites and Hybrid Materials, 4
Lou Z. (2020)
140Mater. Sci. Eng., R.
Zheng X. (2021)
1832Nanoscale, 13
Huang J. (2019)
5Adv. Electron. Mater.
Kai Ke, Vahab Bonab, D. Yuan, I. Manas‐Zloczower (2018)
Piezoresistive thermoplastic polyurethane nanocomposites with carbon nanostructuresCarbon
D. Lipomi, Michael Vosgueritchian, Benjamin Tee, Sondra Hellstrom, Jennifer Lee, Courtney Fox, Zhenan Bao (2011)
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes.Nature nanotechnology, 6 12
Wei H. (2021)
17Chem. Mater., 33
Liu H. (2016)
12977Nanoscale, 8
Song L. (2021)
12ACS Nano, 15
Zhangyin Yan, Shuo Wang, Jialin Bi, Qing(何庆) He, Hao Song, I. Azab, S. El-Bahy, Ashraf Elnaggar, Mina Huang, M. Mahmoud, Junxiang Wang, Qianfei Shao (2022)
Strengthening waterborne acrylic resin modified with trimethylolpropane triacrylate and compositing with carbon nanotubes for enhanced anticorrosionAdvanced Composites and Hybrid Materials, 5
Yujie Zhou, Pengfei Zhan, Miaoning Ren, G. Zheng, K. Dai, Liwei Mi, Chuntai Liu, Changyu Shen (2019)
Significant Stretchability Enhancement of a Crack-Based Strain Sensor Combined with High Sensitivity and Superior Durability for Motion Monitoring.ACS applied materials & interfaces, 11 7
Yijing Qin, D. Schubert (2019)
Simple model to predict the effect of take-up pressure on fibre diameter of PET melt spinningPolymer
Ge G. (2018)
10033Nanoscale, 10
Shuaidi Zhang, Hu Liu, Shuaiyuan Yang, X. Shi, Dianbo Zhang, Chongxin Shan, Liwei Mi, Chuntai Liu, Changyu Shen, Zhanhu Guo (2019)
Ultrasensitive and Highly Compressible Piezoresistive Sensor Based on Polyurethane Sponge Coated with a Cracked Cellulose Nanofibril/Silver Nanowire Layer.ACS applied materials & interfaces, 11 11
Yoshimoto H. (2003)
2077Biomater, 24
Mingxiang Liu, Haikun Wu, Yan Wu, Peitao Xie, R. Pashameah, H. Abo-Dief, S. El-Bahy, Yulei Wei, Guixian Li, Weiting Li, Gemeng Liang, Chunzhao Liu, Kai Sun, R. Fan (2022)
The weakly negative permittivity with low-frequency-dispersion behavior in percolative carbon nanotubes/epoxy nanocomposites at radio-frequency rangeAdvanced Composites and Hybrid Materials, 5
Eun Roh, B. Hwang, Do-Il Kim, B. Kim, N. Lee (2015)
Stretchable, Transparent, Ultrasensitive, and Patchable Strain Sensor for Human-Machine Interfaces Comprising a Nanohybrid of Carbon Nanotubes and Conductive Elastomers.ACS nano, 9 6
Laure Kayser, D. Lipomi (2019)
Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSSAdvanced Materials, 31
Hyunjae Lee, T. Choi, Young Lee, H. Cho, R. Ghaffari, Liu Wang, H. Choi, T. Chung, N. Lu, T. Hyeon, S. Choi, Dae‐Hyeong Kim (2016)
A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy.Nature nanotechnology, 11 6
Li Z. (2020)
1636Soft Matter, 16
M. Qu, F. Nilsson, Yijing Qin, Guanda Yang, Yamin Pan, Xianhu Liu, G. Rodríguez, Jianfan Chen, Chunhua Zhang, D. Schubert (2017)
Electrical conductivity and mechanical properties of melt-spun ternary composites comprising PMMA, carbon fibers and carbon blackComposites Science and Technology, 150
Shuaiguo Zhao, Dandan Lou, Guojie Li, Yanjun Zheng, G. Zheng, K. Dai, Chuntai Liu, Yuanli Jiang, Changyu Shen (2018)
Bridging the segregated structure in conductive polypropylene composites: An effective strategy to balance the sensitivity and stability of strain sensing performancesComposites Science and Technology
Li B. (2020)
181Compos. B
Suji Choi, Sang Han, Dongjun Jung, Hye-jin Hwang, C. Lim, Soochan Bae, O. Park, C. Tschabrunn, Mincheol Lee, Sun Bae, Ji Yu, J. Ryu, Sang-woo Lee, Kyungpyo Park, P. Kang, Won Lee, R. Nezafat, T. Hyeon, Dae‐Hyeong Kim (2018)
Highly conductive, stretchable and biocompatible Ag–Au core–sheath nanowire composite for wearable and implantable bioelectronicsNature Nanotechnology, 13
S. Mannsfeld, Benjamin Tee, R. Stoltenberg, Christopher Chen, Soumendra Barman, B. Muir, A. Sokolov, C. Reese, Zhenan Bao (2010)
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers.Nature materials, 9 10
Dai X. (2020)
3ACS Appl. Polym. Mater., 2
Hong S. H. (2016)
3Adv. Mater. Interfaces
Kaichen Xu, Yusuke Fujita, Yuyao Lu, Satoko Honda, Mao Shiomi, T. Arie, S. Akita, K. Takei (2021)
A Wearable Body Condition Sensor System with Wireless Feedback Alarm FunctionsAdvanced Materials, 33
H. Ziyadi, Mitra Baghali, Mina Bagherianfar, F. Mehrali, R. Faridi‐Majidi (2021)
An investigation of factors affecting the electrospinning of poly (vinyl alcohol)/kefiran composite nanofibersAdvanced Composites and Hybrid Materials, 4
Meifeng Hu, Yang Gao, Yejia Jiang, Huidan Zeng, Songshan Zeng, Mengting Zhu, Gefan Xu, Luyi Sun (2021)
High-performance strain sensors based on bilayer carbon black/PDMS hybridsAdvanced Composites and Hybrid Materials, 4
Qu M. (2022)
427Chem. Eng. J.
R. Liu, Jae Kim, Prashant Dhakal, Wei Li, Jun Ma, Aolin Hou, Cory Merkel, Jingjing Qiu, Mark Zoran, Shiren Wang (2022)
Neuromorphic properties of flexible carbon nanotube/polydimethylsiloxane nanocompositesAdvanced Composites and Hybrid Materials, 6
Bi H. (2018)
1132Sens. Actuators, 171
Zhang X.‐W. (2000)
2739J. Polym. Sci. B, 38
Yuxiang Li, Tengyu He, Liangjing Shi, Ranran Wang, Jing Sun (2020)
Strain Sensor with Both Wide Sensing Range and High Sensitivity Based on Braided Graphene Belts.ACS applied materials & interfaces
Yue X. (2020)
189Compos. Sci. Technol.
Sobhan Sharafkhani, M. Kokabi (2022)
Enhanced sensing performance of polyvinylidene fluoride nanofibers containing preferred oriented carbon nanotubesAdvanced Composites and Hybrid Materials, 5
Amit M. (2019)
30Adv. Funct. Mater.
Zheng Y. (2021)
420Chem. Eng. J.
Zixuan Niu, Weizhong Yuan (2021)
Smart Nanocomposite Nonwoven Wearable Fabrics Embedding Phase Change Materials for Highly Efficient Energy Conversion-Storage and Use as a Stretchable Conductor.ACS applied materials & interfaces
Heo J. S. (2022)
581IEEE J. Biomed. Health Inf., 26
C. Lozano-Pérez, J. Cauich‐Rodríguez, F. Avilés (2016)
Influence of rigid segment and carbon nanotube concentration on the cyclic piezoresistive and hysteretic behavior of multiwall carbon nanotube/segmented polyurethane compositesComposites Science and Technology, 128
Guiyun Xu, Beibei Li, X. Cui, L. Ling, Xiliang Luo (2013)
Electrodeposited conducting polymer PEDOT doped with pure carbon nanotubes for the detection of dopamine in the presence of ascorbic acidSensors and Actuators B-chemical, 188
Fei Y. (2021)
13103J. Mater. Chem. C, 9
Jin-Feng Guan, Jiao Zou, Yi-Ping Liu, Xin-yu Jiang, Jingang Yu (2020)
Hybrid carbon nanotubes modified glassy carbon electrode for selective, sensitive and simultaneous detection of dopamine and uric acid.Ecotoxicology and environmental safety, 201
Nandana Bhardwaj, S. Kundu (2010)
Electrospinning: a fascinating fiber fabrication technique.Biotechnology advances, 28 3
L. Tao, Kunfeng Zhang, H. Tian, Y. Liu, Dan-Yang Wang, Yuan-Quan Chen, Yezhou Yang, T. Ren (2017)
Graphene-Paper Pressure Sensor for Detecting Human Motions.ACS nano, 11 9
Fangyi Guan, Yu Xie, Hanxiang Wu, Yuan Meng, Ye Shi, Meng Gao, Ziyang Zhang, Shiyan Chen, Ye Chen, Hua-ping Wang, Q. Pei (2020)
Silver Nanowire-Bacterial Cellulose Composite Fiber-Based Sensor for Highly Sensitive Detection of Pressure and Proximity.ACS nano
Jun Yang, Jaewan Mun, S. Kwon, Seongjun Park, Z. Bao, Steve Park (2019)
Electronic Skin: Recent Progress and Future Prospects for Skin‐Attachable Devices for Health Monitoring, Robotics, and ProstheticsAdvanced Materials, 31
Li H. (2021)
1795J. Mater. Chem. A, 9
Joo H. (2021)
7Sci. Adv.
Li Y. (2018)
2258J. Mater. Chem. C, 6
Rui Yin, Shuaiyuan Yang, Qianming Li, Shuaidi Zhang, Hu Liu, Jian Han, Chuntai Liu, Changyu Shen (2020)
Flexible conductive Ag nanowire/cellulose nanofibril hybrid nanopaper for strain and temperature sensing applications.Science bulletin, 65 11
Lin J. (2020)
137J. Appl. Polym. Sci.
Miaoning Ren, Yujie Zhou, Yan Wang, G. Zheng, K. Dai, Chuntai Liu, Changyu Shen (2019)
Highly stretchable and durable strain sensor based on carbon nanotubes decorated thermoplastic polyurethane fibrous network with aligned wave-like structureChemical Engineering Journal
Chu Z. (2021)
9634J. Mater. Chem. A, 9
Wang D. (2020)
130Compos. A
Lu L. (2017)
7035J. Mater. Chem. C, 5
Morteza Amjadi, Y. Yoon, I. Park (2015)
Ultra-stretchable and skin-mountable strain sensors using carbon nanotubes–Ecoflex nanocompositesNanotechnology, 26
Xin Zhou, Li Zhu, Li Fan, H. Deng, Q. Fu (2018)
Fabrication of Highly Stretchable, Washable, Wearable, Water-Repellent Strain Sensors with Multi-Stimuli Sensing Ability.ACS applied materials & interfaces, 10 37
IntroductionWith the advent of a new era of flexible wearable devices, strain sensors have gradually become a hot spot of attention in academia and industry.[1–6] Strain sensors have a broad range of encouraging utilization in the areas of human motion monitoring, flexible electronic skin, medical diagnosis, and human‐machine interface.[7–19] Conventional sensors are composed of rigid materials, which are hard and brittle in texture and difficult to curl, and cannot meet the applications in some specific fields, which require stretchable conductors that can maintain stable electrical conductivity even when undergoing large deformations. Conductive polymer composites (CPCs) have good flexibility and good tensile properties to meet the environment of sensors under large tensile (strain ≥ 50%) and bending conditions.Common flexible strain sensors choose flexible polymer materials with good stretchability as substrate layer, including polydimethylsiloxane (PDMS),[20–24] thermoplastic polyurethane elastomer (TPU),[25–27] and Ecoflex.[28,29] Commonly, flexible strain sensors usually incorporate nanometals (such as metal nanoparticles, silver nanowires),[30–32] nanocarbon materials (including carbon black, CNTs, graphene, etc.),[33–45] conductive polymers (including PANI, PPy, and PEDOT:PSS),[46–49] and other conducting materials like Mxene[50–52] as conductive fillers with polymeric substrates to impart excellent electrical conductivity to the composites.A broad detection range and a lower monitoring limit are key criteria for a stretchable and flexible strain sensor. A low monitoring limit of the sensor allows a fast and accurate response to a small strain stimulus, which is crucial for real‐time monitoring of human motions and human health. The wider detection range can satisfy the use of a sensor at a larger strain. In recent years, electrostatic spinning has been widely used as a micro/nanofiber preparation technology due to its preparation of electrospinning membranes with a big specific surface area, large porosity, good mechanical flexibility, and its simple and efficient preparation method.[53–57] Among them, TPU is simply electrostatically spun into fibrous membranes, that exhibit excellent tensile properties, flexibility, and mechanical strength.[58,59] As a kind of emerging nanomaterials, CNTs are also widely used in many fields.[60–64] Selecting suitable materials to prepare various sensors has become the research focus of scholars at home and abroad.[65–71] Li et al.[72] prepared a flexible sensor with a wide monitoring range and ultralow detection limit by ultrasonically anchoring CNTs to TPU electrospun membrane. However, it also shows the disadvantage of a low sensitivity limit, which is less desirable in a condition requiring high sensitivity. The flexible sensors with high sensitivity, good responsiveness, and a wide detection range remain yet to be developed.In this work, TPU fibrous membrane was prepared as a flexible substrate by electrostatic spinning, and the TPU fibrous membrane was coated with dopamine (DA) self‐polymerization (named DT), and CNTs particles were introduced on the substrate by filtration to build the conductive layer (coded as CT and CDT). We systematically studied the impact of introducing a polydopamine layer on the conductive layer, the surface morphologies of the CT sensor as well as the CDT sensor, the mechanical properties of the CT and CDT samples, and the differences in sensing properties during stretching, and the mechanical hysteresis of this samples with the dependencies on different substrate structures.[73–75] A mathematical model leads the understanding of the variation of resistance with strain (Δ R/R0) by using tunneling theory, and is used to analyze the sensitivity between CT and CDT samples caused by the length of neighboring conductive fillers and the amount of conducting routes was analyzed to provide an explanation by calculating the parameters of this mathematical model. The final prepared CDT sensor has a low detection limit (<1%), a broad detecting range (up to 200%), an extremely high sensitivity (Gauge Factor of 10 528.53 at 200% strain), and great cycle stability due to the presence of the polydopamine layer, which can respond accurately to various human movements and even vocalizations.Result and DiscussionPreparation of High Sensitivity SensorThe preparation of stretchable CNTs/DA/TPU flexible strain sensor is illustrated in Figure 1, the experimental details are described in Section 4. We assign a code name of CT for the CNT‐coated TPU flexible strain sensor, and CDT for CNTs/DA/TPU flexible strain sensor.1FigureSchematic diagram of the preparation of CNTs/DA/TPU flexible strain sensor.The morphology of the prepared conductive fibrous membranes is revealed in Figure 2. The surface of pure TPU fibers appears to be relatively even (Figure 2a,b), a small amount of CNTs was loaded on the surface of TPU fibers after binding with CNTs (Figure 2e,f). The surface of DATPU prepared after dopamine coating was rougher (Figure 2c,d), and was completely coated by CNTs after binding with CNTs (Figure 2g,h). This may be caused by that DA underwent self‐polymerization on the TPU surface to form a polydopamine layer and uniformly coated the TPU fibers, which increased the roughness of the fiber surface and was able to bind more CNTs to the surface of the fiber when pumping the same content of CNTs suspension.2Figurea,b) TPU electrospun membrane, c,d) DA/TPU fibrous membrane, e,f) CNTs/TPU flexible strain sensor, g,h) scanning electron microscope images of CNTs/DA/TPU flexible strain sensor.The loading of carbon nanotubes plays a critical role in determining the conductivity of the fibrous membrane. CNTs suspensions of (2.5 mL/5 mL/7.5 mL/10 mL/15 mL) with a concentration of 2 g L−1 were pumped onto TPU electrospun membranes to control the loading of CNTs. The relative resistance of CNTs/TPU flexible strain sensors with different CNTs loadings at 10–50% strain is shown in Figure 3a. The relative resistance of CNTs/TPU flexible sensors showed an increasing trend at 10% and 30% strain with increasing CNT loadings, but the maximum relative resistance of flexible strain sensors with 15 mL of CNTs suspension pumped at 50% strain was about 38.39. However, the maximum relative resistance of a flexible sensor with 15 mL of CNTs suspension at 50% strain was about 38.39, while the maximum relative resistance of a flexible sensor with 10 mL of CNTs suspension is about 59.62, indicating a significant decrease in the relative resistance.3Figurea) The relative resistance of CNTs/TPU flexible strain sensors at 10%, 30%, and 50% strain at CNTs draws from 2.5 to 15 mL, b) sensitivity of CT sensors and CDT sensors in four regions from 0–200% strain, c) typical stress‐strain curves, d) Young's modulus of TPU, DT, CT, and CDT samples and fracture Elongation, e,f) Sensitivity of CT and CDT sensors at 0–200% tensile range per unit strain (GF).The hypothetic reason is that the specimen underwent the process of destruction and reconstruction of conducting network with cyclic stretching, the conductive pathway constructed on the TPU substrate gradually increased as the load of CNTs increased, and the destruction of the conductive pathway increased at the same strain. However, when the loading of CNTs continues to increase to a certain amount, most conductive pathways are still not completely destroyed under larger strains, and the conductive networks of conductive fillers are still lapped, causing a significant decrease in relative resistance. A flexible strain sensor with a 10 mL suspension of CNTs was considered to be an optimal set for the application.Mechanical Properties and Sensing Performance of CT and CDT Flexible Strain SensorsWe further studied the strain sensing performance and mechanism of high gauge factor in the CT and CDT sensors. In general, the GF (Gauge Factor) is a crucial parameter to assess the sensing performance, identified as the ratio of relative resistance change to strain, and can be calculated by Equation (1)1GF=(ΔR/R0)/ε, ε=ΔL/L0\[\begin{array}{*{20}{c}}{GF = \left( {\Delta R{\rm{/}}{R_0}} \right){\rm{/}}\varepsilon ,\;\varepsilon = \Delta L{\rm{/}}{L_0}}\end{array}\]where the R0 and ε are the initial resistance and applied strain, respectively. Δ R is the difference between the real‐time resistance and the initial resistance.Figure 3b compares the sensitivity of CT and CDT flexible strain sensors in four regions from 0–200% strain, where the GF values of CT flexible strain sensor are 109.96 (0–50% strain), 247.13 (50–100% strain), 515.19 (100–150% strain), and 928.85 (150–200% strain), respectively. The GF values of CDT flexible strain sensors were 208.89 (0–50% strain), 912.81 (50–100% strain), 3950.69 (100–150% strain), and 15 794.45 (150–200% strain). It can be observed that the gauge factors of the CDT sensor are higher than those of the CT sensor in all strain regions, empowered by the polydopamine layer‐wrapped fiber surface. Figure 3c shows the typical stress–strain curves of the conductive composite fibrous membrane, the tensile strength of the prepared pure TPU fibrous membrane is 6.49 ± 0.12 MPa, and the tensile strength of the DATPU fibrous membrane is 6.58 ± 0.11 MPa, the tensile strength of the dopamine‐coated TPU fibrous membrane is increased by about 0.1 MPa. In addition, the tensile strength of the prepared CT sensor is 6.24±0.21 MPa for the CT sensor and 6.31±0.15 MPa for the CDT sensor, it can be observed that the tensile strength of the TPU fibrous membrane increased after being coated with dopamine, which interacts more strongly with it.In addition, Young's modulus of pure TPU fibrous membrane in Figure 3d reached 0.73 MPa and the elongation at break was 631% ± 37%. Young's modulus of the DATPU fiber membrane reached 0.98 MPa and the elongation at break was 596% ± 34%. With the introduction of dopamine, Young's modulus of fibrous membranes increased significantly, however, the elongation at break decreased, probably due to the strong bonding ability between the PDA coating and TPU fibers and the strong inter‐ and intramolecular hydrogen bonding exhibited by both the PDA coating and the PDA and TPU matrix.[76] Also compared to CT (Young's modulus 0.97 MPa, elongation at break 574% ± 33%), Young's modulus of CDT was more significantly improved by 0.27 MPa with a Yang's modulus of 1.24 MPa, nevertheless, its elongation also decreased significantly with a CDT elongation at break of 488% ± 30%, which could be attributed to the polydopamine layer and more CNTs attached between the fibers, which helps to reduce the slip between fibers.[77] To further compare the sensitivity of CT sensor with that of the CDT sensor, the GFs of both sensors were compared at 0–200% strain, corresponding to 399.66 and 5322.82 for CT and CDT, respectively, further illustrating the better responsiveness of CDT (Figure 3e,f).Mechanical Hysteresis of Strain SensorThe long‐term stability, as well as the durability of sensors, are important for applications in detecting real‐time motion. Figure 4a,b shows the cyclic loading and unloading curves for 20 cycles at 10% strain for the CT and CDT sensors, respectively, with the red line showing the first cycle and the blue line showing cycles 2–20. Mechanical hysteresis (HM) is an effective indicator to guide the construction of an internal conductive network of CT and CDT sensors, as we need to minimize HM when the sensors undergo multiple loading and unloading cycles.[73,74] From Figure 4c, the (AL–AU) area and the AU area are represented in orange and green, respectively. The HM value could be measured from Equation (2) as follows:2HM=|AL−AU|AL \[\begin{array}{*{20}{c}}{{H_{\rm{M}}} = \frac{{\left| {{A_{\rm{L}}} - {A_{\rm{U}}}} \right|}}{{{A_{\rm{L}}}}}\;}\end{array}\]where AL is the integral area of the loading curve to the x‐axis and AU is the integral area of the unloading curve to the x‐axis.4Figurea,b) Cyclic stress‐strain curves of CT and CDT sensors at 10% strain, c) mechanical hysteresis (HM) quantification schematic, d) HM of CT and CDT sensors at 10% strain for 20 cycles of stretching, e) cycling stress–strain curves of CDT sensors at the strain range of 10–90%, f) HM of CDT sensors at 10–90% strain for cyclic stretching.The HM of the CT and CDT sensors were calculated separately for 20 cycles at 10% strain in Figure 4d. The results showed that the polydopamine‐coated fibrous membrane exhibited a lower HM. During the first cycle, the HM was 61.53% and 60.99% for the CT and CDT, respectively, with little difference. However, during the 2–20 cycles, the average HM of CT and CDT decreased to 41.60% and 37.97%, respectively. This is due to the plastic deformation as well as the elastic deformation of TPU during the stretching–recovery process. In the first loading and unloading process, the conductive pathways of CNTs fractured for the first time, resulting in higher tensile stress in the first loading curve. In the process of unloading, TPU fibrous membrane returned to its initial state and without any distortion, thus exhibiting a relatively high HM.[68] The sensors underwent the same process during subsequent stretching as well as recovery, but the plastic deformation of the TPU under external forces during unloading was permanent owing to the hysteresis effect of the composite and stabilized the HM of the samples after several stretching cycles.[73,74]The CDT sensor exhibited a lower HM during subsequent cycles, indicating that the CDT sample exhibited lower energy consumption as well as more excellent long‐term durability than the CT sample during multiple cycles of stretching. Figure 4e,f shows the twentieth cyclic stress–strain curves of the CDT sensor at five strains from 10% to 90% and their corresponding HM, respectively. The data demonstrate that the HM of the sensor at 30%, 50%, 70%, and 90% strains do not differ significantly, further demonstrating the good cyclic stability of the CDT sensor.Theoretical Understanding of Conductive Fillers Enabled Strain SensingFigure 5a exhibits the CNTs content as well as the polydopamine layer coated on TPU in CT as well as CDT sensors determined by thermogravimetric analysis (TGA), which can be calculated by the following equation3mCT=mCNTs1 +mTPU\[\begin{array}{*{20}{c}}{{m_{{\rm{CT}}}} = {m_{{\rm{CNTs}}1}}\; + {m_{{\rm{TPU}}}}}\end{array}\]4b·mCT=mCNTs1 +a·mTPU\[\begin{array}{*{20}{c}}{b\cdot{m_{{\rm{CT}}}} = {m_{{\rm{CNTs}}1}}\; + a\cdot{m_{{\rm{TPU}}}}}\end{array}\]5WCNTs1=mCNTs1mCT =b−a1−a \[\begin{array}{*{20}{c}}{{W_{{\rm{CNTs}}1}} = \frac{{{m_{{\rm{CNTs}}1}}}}{{{m_{{\rm{CT}}}}}}\; = \frac{{b - a}}{{1 - a}}\;}\end{array}\]6mDT=mDA +mTPU\[\begin{array}{*{20}{c}}{{m_{{\rm{DT}}}} = {m_{{\rm{DA}}}}\; + {m_{{\rm{TPU}}}}}\end{array}\]7c·mDT=mDA +a·mTPU\[\begin{array}{*{20}{c}}{c\cdot{m_{{\rm{DT}}}} = {m_{{\rm{DA}}}}\; + a\cdot{m_{{\rm{TPU}}}}}\end{array}\]8WDA=mDAmDT =c−a1−a \[\begin{array}{*{20}{c}}{{W_{{\rm{DA}}}} = \frac{{{m_{{\rm{DA}}}}}}{{{m_{{\rm{DT}}}}}}\; = \frac{{c - a}}{{1 - a}}\;}\end{array}\]9mCDT=mCNTs2 +mDT\[\begin{array}{*{20}{c}}{{m_{{\rm{CDT}}}} = {m_{{\rm{CNTs}}2}}\; + {m_{{\rm{DT}}}}}\end{array}\]10d·mCDT=mCNTs2 +c·mDT\[\begin{array}{*{20}{c}}{d\cdot{m_{{\rm{CDT}}}} = {m_{{\rm{CNTs}}2}}\; + c\cdot{m_{{\rm{DT}}}}}\end{array}\]11WCNTs2=mCNTs2mCDT =d−c1−c \[\begin{array}{*{20}{c}}{{W_{{\rm{CNTs}}2}} = \frac{{{m_{{\rm{CNTs}}2}}}}{{{m_{{\rm{CDT}}}}}}\; = \frac{{d - c}}{{1 - c}}\;}\end{array}\]where mTPU, mCNTs, mDA, and mDT are the weights of pure TPU fibrous membrane, carbon nanotubes, dopamine layer, and DATPU fibrous membrane in the sensor, respectively. mCT and mCDT are the total weights of the CT sensor and CDT sensor, respectively. For the CT sensor, the residual weight ratio of the pure TPU fibrous membrane measured after thermal degradation of the sample is a and the residual weight ratio of the CT sensor is b. Therefore, the content of CNTs in the CT sensor (WCNTs1) is calculated as 15.55% according to Equation (5). For the CDT sensor, the residual thermogravimetric ratio of DATPU after thermal degradation of the sample is c, and the residual weight ratio of the CDT sensor is d. First, the content of dopamine (WDA) coated on TPU fiber can be calculated as 0.9% according to Equation (8), and then the content of CNTs in the CDT sensor (WCNTs2) can be calculated by Equation (11) as 17.73%. The results show that the loading of CNTs in the CDT sensor is higher than that in the CT sensor, which can further indicate that the roughness of the fiber surface can be increased due to the coating of the polydopamine layer on the TPU fibers, and more CNTs can be anchored on the fiber surface. Due to the strong interaction between the OH in the polydopamine layer and the COOH in the CNTs, more CNTs are anchored on the fiber surface.[78–80]5Figurea) Thermogravimetric analysis of pure TPU fibrous membrane, DT fibrous membrane, CT, and CDT sensor, b) optical photos of four samples, c) demonstration of a single fiber during CDT sensor preparation.Resistance Fitting Model for SensorsThe attachment of polydopamine onto the TPU fiber surface has a significant effect on the formation of the conductive network. At the microstructural level, the total resistance of CT as well as CDT sensors can be seen as a function of the R of every conducting filler and the resin matrix.[12,81] The conductive fillers and conductive paths in the conductive network can be visualized as a function of the total resistance by means of a relationship curve between relative resistance and strain. The following equation is used to express the total resistance Equation (12).[75]12R =M(Rm+Rc)N \[\begin{array}{*{20}{c}}{R\; = \frac{{M\left( {{R_{\rm{m}}} + {R_{\rm{c}}}} \right)}}{N}\;}\end{array}\]where R, Rm, and Rc are the total resistance of the final composite, the resistance between two neighboring conductive fillers, and the resistance of a single conductive filler, respectively. For electrically conductive composites, Rm is far greater than Rc, so Rm+Rc ≈ Rm. M is the amount of fillers building a conductive path and N is the amount of conductive paths formed. On the basis of the tunneling effect theory, the resistance relationship can be expressed by the following equation.[12,82]13Rm=8πhs3c2re2exp(rs), r=4πh2meφ\[\begin{array}{*{20}{c}}{{R_{\rm{m}}} = \frac{{8\pi hs}}{{3{c^2}r{e^2}}}\exp \left( {rs} \right),\:r = \frac{{4\pi }}{h}\sqrt {2{m_{\rm{e}}}\varphi } }\end{array}\]Substituting Equations (3–13) into (3–12) gives14R =MN [8πhs3c2re2exp(rs)]\[\begin{array}{*{20}{c}}{R\; = \frac{M}{N}\;\left[ {\frac{{8\pi hs}}{{3{c^2}r{e^2}}}{\rm{exp}}\left( {rs} \right)} \right]}\end{array}\]where h is Planck's constant, c2 is the effective cross‐section, e is the electron charge, s is the average distance between neighboring conducting fillers, me is the electron mass, and φ is the height of tunneling potential barrier.As stress is applied to the sensor, the tunneling distance between CNTs particles increases, and there is a process of destruction and reconstruction of the conducting path within the conducting network. Assuming that the tunneling distance between neighboring conducting particles satisfies a linear function from s0 to s and the number of conducting paths satisfies an exponential function from N0 to N, they can be calculated as follows:15s =s0 (1+Ax)\[\begin{array}{*{20}{c}}{s\; = {s_0}\;\left( {1 + Ax} \right)}\end{array}\]16N =N0 exp[f(x)]\[\begin{array}{*{20}{c}}{N\; = {N_0}\;{\rm{exp}}\left[ {f\left( x \right)} \right]}\end{array}\]where s0 and N0 are the initial conductive particle distance and the initial conductive path number, respectively. x is the applied strain and f(x) is a function of the strain x. A is a constant that relies on the type of conductive filler and the measurement conditions. ΔR/R0 can be obtained by substituting Equation (17).17 ΔRR0=R−R0R0 =RR0 −1 =(ss0×N0N) exp[r(s−s0)]−1=(1+Ax) exp[r(s−s0)−f(x)]−1\[\begin{array}{*{20}{c}}{\begin{array}{*{20}{c}}{\;\frac{{\Delta R}}{{{R_0}}} = \frac{{R - {R_0}}}{{{R_0}}}\; = \frac{R}{{{R_0}}}\; - 1\; = \left( {\frac{s}{{{s_0}}} \times \frac{{{N_0}}}{N}} \right)\;{\rm{exp}}\left[ {r\left( {s - {s_0}} \right)} \right] - 1}\\{ = \left( {1 + Ax} \right)\;{\rm{exp}}\left[ {r\left( {s - {s_0}} \right) - f\left( x \right)} \right] - 1}\end{array}}\end{array}\]where [r(s − s0) − f(x)] can be used to express the relationship between the tunneling potential height (φ) and the number of varying conducting paths (N), as Equation (18):18bxc=[r(s−s0)−f(x)] \[\begin{array}{*{20}{c}}{b{x^c} = \left[ {r\left( {s - {s_0}} \right) - f\left( x \right)} \right]\;}\end{array}\]Substituting Equation (18) into Equation (17), ΔR/R0 can then be expressed as a function of strain x, as shown in Equation (19).19ΔRR0=(1+Ax) exp(bxc)−1\[\begin{array}{*{20}{c}}{\frac{{\Delta R}}{{{R_0}}} = \left( {1 + Ax} \right)\;{\rm{exp}}\left( {b{x^c}} \right) - 1}\end{array}\]where A, b, and c are constants.For Equation (16), in the actual stretching case, the conductive path of the sensor will be gradually broken upon stretching, the number of conductive paths will gradually decrease with rising strain until all conductive paths break (N → 0) and the sensor conductive failure, the calculation limit of which is shown below20af (x)= lnNN0\[\begin{array}{*{20}{c}}{f\;\left( x \right) = \;\ln \frac{N}{{{N_0}}}}\end{array}\]20blimN→0f (x)=limN→0lnNN0 = −∞\[\begin{array}{*{20}{c}}{\mathop {\lim }\limits_{N \to 0} f\;\left( x \right) = \mathop {\lim }\limits_{N \to 0} \ln \frac{N}{{{N_0}}}\; = \; - \infty }\end{array}\]Then substituting [f(x) → −∞] into Equation (16), we get21bxc=[r(s−s0)−f(x)] ≈−f(x)\[\begin{array}{*{20}{c}}{b{x^c} = \left[ {r\left( {s - {s_0}} \right) - f\left( x \right)} \right]\; \approx - f\left( x \right)}\end{array}\]22NN0= exp(−bxc)\[\begin{array}{*{20}{c}}{\frac{N}{{{N_0}}} = \;{\rm{exp}}\left( { - b{x^c}} \right)}\end{array}\]Figure 6a shows the experimental curve of ΔR/R0 depending on the strain fitted based on the model of Equation (19). These parameters (A, b, c) calculated from the experimental test results and R2 are shown in Table 1. The calculated data indicate that the model Equation (19) can well verify and describe the relative resistance versus strain of CT as well as CDT sensors, and matches well with the actual test results. Figure 6b,c shows the simulated conductive path variation ratio N/N0 and conductive interparticle distance variation ratio s/s0 versus strain based on the parameters in Table 1 and Equations (22) and (15). In Figure. 6b, according to the fitting results, it can be seen that when the strain reaches 200%, the N/N0 of the CT sample is 0.14 and the N/N0 of the CDT sample is 0.02. It could be observed that the number of conducting paths of the CDT sample is closer to 0 at 200% strain, and the conductive paths in the conductive network decrease faster, which may be due to the fact that the polydopamine layer is wrapped on the TPU fiber. During the stretching, the polydopamine layer cracked and formed a special lamellar structure on the surface of TPU nanofiber, which accelerated the migration of more CNTs loaded on the polydopamine layer, leading to a faster reduction in the number of conductive paths. In Figure 6c, the slope (s/s0) for the CDT sample is greater, and the distance between the conducting particles changes faster, which well verifies the previous conjecture that the CDT sensor works as shown in Figure 6d.6Figurea) Fit function of ΔR/R0 versus strain for CT and CDT sensors and theoretical data, b) Fit function of conductive path number for CT and CDT sensors, c) Fit function of distance between conductive particles for CT and CDT sensors, d) Schematic diagram of CDT sensor operating principle.1TableModel calculation parameters of Equation (19)AbcR2CT0.667 ± 0.200.010 ± 0.0111.000 ± 0.1840.9902CDT0.982 ± 0.250.062 ± 0.0031.222 ± 0.0650.9993Based on the numerical model constructed by Equation (19), the parameters (A,b,c) can visualize the level of change in the number of conductive paths and the level of change in the distance between conductive particles during the stretching process. For CT samples and CDT samples, the presence of polydopamine layers can affect the values of three parameters (Table 1). The parameter A represents the changing rate of the distance between the conducting fillers of adjacent CNTs, and the larger value of A for CDT samples compared to CT samples indicates that the distance between the conductive particles of CDT samples increases faster during stretching. Parameters b and c represent the change in conductive paths and are of great importance when analyzing the conductivity and sensitivity of the sensor. The larger values of b and c for the CDT samples compared to the CT samples indicate that the CDT samples have higher sensitivity. Normally, the interval between neighboring conducting fillers and conducting paths is difficult to measure. Equations (15) and (22) can accurately predict the change in distance between conductive fillers and the change in the number of conductive paths during the stretching. These mathematical models have been effective in predicting the change in conductive paths and neighboring conducting fillers.Sensing Performance of CDT SensorsFigure 7a,b shows the repetitive electrical signal response of the CDT sensor for ten cycles at 10%, 20%, and 30% strain and 50%, 70%, and 100% strain, respectively, and it can be seen that the prepared CDT sample has good responsiveness. Figure 7c,d shows the I–V curves of the CDT sensor at microstrain (0–10%) and large strain (30–200%). The I–V curves of the CDT sample for a gradual increase of voltage from −6 to 6 V are in strict accordance with Ohm's law, which indicates good reliability.7Figurea,b) ΔR/R0change of CDT sensor under cyclic stretching at 10–100% strain, c,d) I–V curves of CDT sensor at different micro‐strains and large strains, e) CDT sensor response to fast stretching, f) relative resistance change of CDT sensor at different strains for three cycles, g) CDT sensor tested for 300 cycles at 10% strain at a stretching speed of 100 mm min−1.Figure 7e shows the response time measured by rapidly stretching the CDT sensor at 1% strain with a stretching rate of 200 mm min−1. At the loading stage, the resistance of the CDT sensor rises quickly after the strain is applied, and the response time is 188 ms. At the unloading stage, the resistance of the CDT sensor declines quickly after the strain is withdrawn, and the response time is 221 ms, with a difference of 33 ms. The response time increases slightly in the unloading, which may be due to the fact that the recovery of the polydopamine layer wrapped on TPU fibers at a very fast stretching speed requires more time, leading to the delayed re‐lap of the conductive network. Figure 7f shows three cycles of testing of the CDT sample from 10% to 190% strain at each strain increase of 20%. It could be observed that the CDT sensor responds accurately to each stage of strain, further verifying that the CDT sensor has good reliability. In Figure 7g, the CDT sensor was tested for 300 cycles at 10% strain at a stretching speed of 100 mm min−1, and the results showed that the CDT sensor has good stability in long‐term usage.Application of CDT Sensors in Human Motion MonitoringBased on the good stability and flexibility, high sensitivity, and fast response capability of the CDT sensor fabricated in this work, it can be employed to monitor the movement of the human body in real‐time (Figure 8a–f). As illustrated in Figure 8a,b, the resistance of the CDT sensor gradually increases with the bending of the finger at different bending angles (30°, 60°, and 90°) and returns to the initial position when the finger returns to its original position. In Figure 8c, when the CDT is deployed on the wrist, the CDT sensor can react to the twisting and extension of the wrist with a regular electrical signal. At the same time, the CDT sensor reacts regularly and accurately to the motions of the arm and knee (Figure 8d,e).8FigureSensing application of CDT strain sensors in human motion. a) finger flexion, b) finger flexion at 30°, 60°, 90°, c) wrist flexion, d) elbow flexion, e) knee flexion, f) head up and down, g) speaking schematic.When the CDT sensor was attached to the neck of the volunteer (Figure 8f), it responds to the strain caused by raising and lowering the head. The CDT sensor could not only monitor large human movements but also accurately respond to the vibration of vocal folds when saying different syllables—“Hola” and “Harbin”, with its excellent pressure‐sensitive characteristics. By analyzing the precise sensing signal including the frequency of peaks and the height of peaks in the vocal cord vibration signal, we can interpret the number of words spoken, the frequency of speech, and the volume of speech, which can be utilized to develop technology to help people with a speech impairment to communicate. Therefore, the CDT sensor demonstrates significant potential in the applications such as wearable devices and human–machine interfaces.ConclusionThe high‐performance flexible strain sensors were prepared by loading CNTs on electrospun TPU fibrous membranes and demonstrated high sensitivity, wide detection range, good responsiveness, low price, and easy to produce on a large industrial scale. Due to the hydrogen bond interaction and strong interaction between the OH in the polydopamine layer and the COOH in the carbon nanotubes, more carbon nanotubes are fixed on the fiber surface and accelerates the migration of CNTs by forming a split‐layer structure when the polydopamine layer is stretched, which exhibits a faster change in resistance under stress. A mathematical model constructed by tunnel theory is used to predict the variation of conductive filler and conductive path with strain in CT and CDT samples. We find that the dopamine layer can change the fiber structure of the electrospun membrane and used it to explain the origin of the huge gauge factor of the flexible sensors. Owing to the high sensitivity of CDT sensors, they can be applied to the detection of small strains and various human motions.Experimental SectionMaterialsTPU (Elastollan 1185A), density 1.05 g cm−3, was provided by BASF Co., Ltd. Carbon nanotubes (MWCNT‐COOH, diameter from 20 to 40 nm, length < 5 microns) were purchased from Shenzhen Nanotech Port Co., Ltd. N,N‐dimethylformamide (DMF) and tetrahydrofuran (THF) were purchased from Tianjin Fuyu Fine Chemical Co., Ltd. Dopamine hydrochloride (DA⋅HCl) and Sodium periodate (NaIO4) were purchased from Shanghai Macklin Biochemical Co., Ltd. Tris (hydroxymethyl) aminomethane (Tris) was purchased from Fuzhou Feijing Biological Technology Co., Ltd.Preparation of TPU Fibrous Membrane through ElectrospinningTPU fibrous membranes were prepared using the electrostatic spinning technique. First, TPU particles with a mass fraction of 20% were dissolved in a mixture of DMF/THF (mass ratio of 1:1). The mixture was mechanically stirred at room temperature for 5 h to obtain a homogeneous spinning solution. Then, the spinning solution was injected into a syringe with a capacity of 15 mL for electrostatic spinning. Aluminum foil was chosen to be laid on the roller as the receiving device for TPU fibers, the receiving distance between the needle and receiving rollers was 20 cm, and electrostatic spinning was carried out at 20 kV and the liquid supply rate was 1 mL h−1. Lastly, the prepared fiber films were dried at 85 °C for 5 h to eliminate the residual organic solvent.Preparation of Dopamine‐Coated TPU Fibrous MembraneFirst, the TPU fibrous membrane was repeatedly washed with purified water to eliminate surface pollutants and then dried in an oven at 65 °C for 3 h. The TPU nanofibers mats were coated and finely modified using the fast polydopamine coating method (fPDAc),[83,84] specifically an aqueous solution of DA/tris (10 mm, pH 8.5) at 2.0 g L−1 and DA with NaIO4 (10 mm, pH 8.5) with a molar ratio of 0.5 was immediately mixed, and the TPU electrospun membrane was immersed in it and stirred continuously, and the surface of the TPU electrospun membrane changed from light pink to brown with the spontaneous deposition of the attached polydopamine (PDA) layer. Finally, the PDA‐coated TPU fibrous membrane was rinsed with purified water for 30 min and dried in an oven at 65 °C for 3 h to produce the DATPU fibrous membrane.Preparation of CNTs/TPU and CNTs/DATPU Strain SensorsFirst, 2.0 g L−1 of CNTs aqueous solution was sonicated for 2 h to produce a uniformly dispersed CNTs suspension. Then, the TPU electrospun membrane and DATPU film were cut into 50 mm × 50 mm sizes, and the CNTs suspension was filtered onto the TPU electrospun membrane and DATPU film with 2.5, 5, 7.5, 10.5, 15 mL, and a certain amount and rinsed three times with purified water and dried at 80 °C. Finally, filtered CNTs of TPU electrospun membrane and DATPU film were cut into 10 mm × 40 mm segments and connected to wires for the convenience of testing as CT and CDT flexible strain sensors.CharacterizationScanning electron microscopy (SEM, Volumescope2, Thermo Scientific, America) was employed to observe the morphology of the samples at an accelerating voltage of 5 kV.Tensile tests were performed with an electronic universal testing apparatus (UTM2203, SUN, China) equipped with a 2 kN transducer at a rate of 50 mm min−1. All specimens are in the size of 40 mm × 10 mm with an applied length of 20 mm. 5 tests were performed on all specimens and the average value was taken.To acquire the I–V curves of the sensors, static resistance measurements were performed with a digital source meter (Keithley 2400, USA) at an applied voltage(−6 to + 6 V).The sensing performance was characterized by the digital source meter (Keithley 2400) in conjunction with a UTM2203 electronic universal testing machine. A sensor sample of size 40 mm × 10 mm was first fixed on the universal mechanical testing machine at a distance of 20 mm from both ends of the fixture, after which the digital source meter was connected to either end of the sensor and used to test the resistance versus strain of the CT and CDT sensors at a constant tensile rate of 10 mm min−1. The relative resistance change can be calculated by Equation (23).23ΔR/R0=(R−R0)R0\[\begin{array}{*{20}{c}}{\Delta R{\rm{/}}{R_0} = \left( {R - {R_0}} \right){R_0}}\end{array}\]where R0 is the initial resistance when ε = 0% and R is the real‐time resistance that varies with strain.Informed consent was obtained for all participants involved in the experiments testing the applications of the sensors. In addition, institutional review board approval was not required to perform these experiments.AcknowledgementsX.Y. and Z.W. contributed equally to this work. This work was supported by Open Project Fund of the Key Laboratory of Engineering Dielectrics and Its Application (2018EDAQY05), Heilongjiang Province Postdoctoral Funded Project (LBH‐Q21019), University Nursing Program for Young Scholars with Creative Talents in Heilongjiang Province (UNPYSCT‐2018214), Heilongjiang Natural Science Foundation (LH2020E087), and the Engineering and Physical Sciences Research Council (EPSRC, UK) grant‐EP/N007921.Conflict of InterestThe authors declare no conflict of interest.Data Availability StatementThe data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.N. Wen, L. Zhang, D. Jiang, Z. Wu, B. Li, C. Sun, Z. Guo, J. Mater. Chem. A 2020, 8, 25499.M. Fan, L. Wu, Y. Hu, M. Qu, S. Yang, P. Tang, L. Pan, H. Wang, Y. Bin, Adv. Compos. Hybrid Mater. 2021, 4, 1039.D. Zhang, M. Zhang, J. Wang, H. Sun, H. Liu, L. Mi, C. Liu, C. Shen, Adv. Compos. Hybrid Mater. 2022, 5, 1812.M. Hu, Y. Gao, Y. Jiang, H. Zeng, S. Zeng, M. Zhu, G. Xu, L. Sun, Adv. Compos. Hybrid Mater. 2021, 4, 514.X. Chang, L. Chen, J. Chen, Y. Zhu, Z. Guo, Adv. Compos. Hybrid Mater. 2021, 4, 435.Y. Shen, W. Yang, F. Hu, X. Zhang, Y. Zheng, H. Liu, H. Algadi, K. Chen, Adv. Compos. Hybrid Mater. 2023, 6, 21.X. Liu, Z. Wu, D. Jiang, Adv. Compos. Hybrid Mater. 2022, 5, 1712.J. C. Yang, J. Mun, S. Y. Kwon, S. Park, Z. Bao, S. Park, Adv. Mater. 2019, 31, 1904765.D. J. Lipomi, M. Vosgueritchian, B. C. Tee, S. L. Hellstrom, J. A. Lee, C. H. Fox, Z. Bao, Nat. Nanotechnol. 2011, 6, 788.X. Yue, Y. Jia, X. Wang, K. Zhou, W. Zhai, G. Zheng, K. Dai, L. Mi, C. Liu, C. Shen, Compos. Sci. Technol. 2020, 189, 108038.S. Wang, Y. Fang, H. He, L. Zhang, C. a. Li, J. Ouyang, Adv. Funct. Mater. 2020, 31, 2007495.J. Huang, D. Li, M. Zhao, A. Mensah, P. Lv, X. Tian, F. Huang, H. Ke, Q. Wei, Adv. Electron. Mater. 2019, 5, 1900241.M. Amit, L. Chukoskie, A. J. Skalsky, H. Garudadri, T. N. Ng, Adv. Funct. Mater. 2019, 30, 1905241.T. Q. Trung, N. E. Lee, Adv. Mater. 2016, 28, 4338.Z. Lou, L. Wang, K. Jiang, Z. Wei, G. Shen, Mater. Sci. Eng., R. 2020, 140, 100523.S. Choi, S. I. Han, D. Jung, H. J. Hwang, C. Lim, S. Bae, O. K. Park, C. M. Tschabrunn, M. Lee, S. Y. Bae, J. W. Yu, J. H. Ryu, S. W. Lee, K. Park, P. M. Kang, W. B. Lee, R. Nezafat, T. Hyeon, D. H. Kim, Nat. Nanotechnol. 2018, 13, 1048.H. Lee, T. K. Choi, Y. B. Lee, H. R. Cho, R. Ghaffari, L. Wang, H. J. Choi, T. D. Chung, N. Lu, T. Hyeon, S. H. Choi, D. H. Kim, Nat. Nanotechnol. 2016, 11, 566.H. Joo, Y. Lee, J. Kim, J. S. Yoo, S. Yoo, S. Kim, A. K. Arya, S. Kim, S. H. Choi, N. Lu, H. S. Lee, S. Kim, S. T. Lee, D. H. Kim, Sci. Adv. 2021, 7, eabd4639.K. Xu, Y. Fujita, Y. Lu, S. Honda, M. Shiomi, T. Arie, S. Akita, K. Takei, Adv. Mater. 2021, 33, 2008701.S. C. Mannsfeld, B. C. Tee, R. M. Stoltenberg, C. V. Chen, S. Barman, B. V. Muir, A. N. Sokolov, C. Reese, Z. Bao, Nat. Mater. 2010, 9, 859.D. Wang, Y. Lin, D. Hu, P. Jiang, X. Huang, Compos. A 2020, 130, 105754.Z. Chu, W. Jiao, Y. Huang, Y. Zheng, R. Wang, X. He, J. Mater. Chem. A 2021, 9, 9634.X. Zhou, L. Zhu, L. Fan, H. Deng, Q. Fu, ACS Appl. Mater. Interfaces 2018, 10, 31655.Z. H. Yang, Z. J. Wu, D. W. Jiang, J. Mater. Chem. C 2021, 8, 11.H. Liu, J. Gao, W. Huang, K. Dai, G. Zheng, C. Liu, C. Shen, X. Yan, J. Guo, Z. Guo, Nanoscale 2016, 8, 12977.L. Lin, Y. Choi, T. Chen, H. Kim, K. S. Lee, J. Kang, L. Lyu, J. Gao, Y. Piao, Chem. Eng. J. 2021, 419, 129513.K. Ke, V. Solouki Bonab, D. Yuan, I. Manas‐Zloczower, Carbon 2018, 139, 52.M. Amjadi, Y. J. Yoon, I. Park, Nanotechnology 2015, 26, 375501.M. Xu, J. Qi, F. Li, Y. Zhang, Nanoscale 2018, 10, 5264.L. Lu, X. Wei, Y. Zhang, G. Zheng, K. Dai, C. Liu, C. Shen, J. Mater. Chem. C 2017, 5, 7035.F. Guan, Y. Xie, H. Wu, Y. Meng, Y. Shi, M. Gao, Z. Zhang, S. Chen, Y. Chen, H. Wang, Q. Pei, ACS Nano 2020, 14, 15428.G. J. Zhu, P. G. Ren, J. Wang, Q. Duan, F. Ren, W. M. Xia, D. X. Yan, ACS Appl. Mater. Interfaces 2020, 12, 19988.S. Zhang, H. Liu, S. Yang, X. Shi, D. Zhang, C. Shan, L. Mi, C. Liu, C. Shen, Z. Guo, ACS Appl. Mater. Interfaces 2019, 11, 10922.R. Yin, S. Yang, Q. Li, S. Zhang, H. Liu, J. Han, C. Liu, C. Shen, Sci. Bull. 2020, 65, 899.D. Jiang, Y. Wang, B. Li, C. Sun, Z. Wu, H. Yan, L. Xing, S. Qi, Y. Li, H. Liu, W. Xie, X. Wang, T. Ding, Z. Guo, Polym. Rev. 2019, 304, 1900074.Y. Zhou, P. Zhan, M. Ren, G. Zheng, K. Dai, L. Mi, C. Liu, C. Shen, ACS Appl. Mater. Interfaces 2019, 11, 7405.Z. Niu, W. Yuan, ACS Appl. Mater. Interfaces 2021, 13, 4508.M. Qu, H. Wang, Q. Chen, L. Wu, P. Tang, M. Fan, Y. Guo, H. Fan, Y. Bin, Chem. Eng. J. 2022, 427, 131648.J. S. Heo, R. Soleymanpour, J. Lam, D. Goldberg, E. Large, S. K. Park, I. Kim, IEEE J. Biomed. Health Inf. 2022, 26, 581.Y. Fei, F. Chen, W. Fang, A. Hejna, L. Xu, T. Liu, M. Zhong, J. Yang, T. Kuang, J. Mater. Chem. C 2021, 9, 13103.B. Li, J. Luo, X. Huang, L. Lin, L. Wang, M. Hu, L. Tang, H. Xue, J. Gao, Y.‐W. Mai, Compos. B 2020, 181, 107580.Q. Zheng, J.‐h. Lee, X. Shen, X. Chen, J.‐K. Kim, Mater. Today 2020, 36, 158.Y. Li, T. He, L. Shi, R. Wang, J. Sun, ACS Appl. Mater. Interfaces 2020, 12, 17691.L. Q. Tao, K. N. Zhang, H. Tian, Y. Liu, D. Y. Wang, Y. Q. Chen, Y. Yang, T. L. Ren, ACS Nano 2017, 11, 8790.M. Qu, F. Nilsson, Y. Qin, G. Yang, Y. Pan, X. Liu, G. Hernandez Rodriguez, J. Chen, C. Zhang, D. W. Schubert, Compos. Sci. Technol. 2017, 150, 24.L. V. Kayser, D. J. Lipomi, Adv. Mater. 2019, 31, 1806133.X. Wang, J. Zhou, Y. Zhu, W. Cheng, D. Zhao, G. Xu, H. Yu, Chem. Eng. J. 2020, 392, 123644.E. Roh, B. U. Hwang, D. Kim, B. Y. Kim, N. E. Lee, ACS Nano 2015, 9, 6252.G. Ge, Y. Cai, Q. Dong, Y. Zhang, J. Shao, W. Huang, X. Dong, Nanoscale 2018, 10, 10033.Y. Zheng, R. Yin, Y. Zhao, H. Liu, D. Zhang, X. Shi, B. Zhang, C. Liu, C. Shen, Chem. Eng. J. 2021, 420, 127720.W. Chen, L. X. Liu, H. B. Zhang, Z. Z. Yu, ACS Nano 2021, 15, 7668.X. Zheng, J. Shen, Q. Hu, W. Nie, Z. Wang, L. Zou, C. Li, Nanoscale 2021, 13, 1832.N. Bhardwaj, S. C. Kundu, Biotechnol. Adv. 2010, 28, 325.H. Yoshimoto, Y. M. Shin, H. Terai, J. P. Vacanti, Biomater 2003, 24, 2077.Y. Qin, D. W. Schubert, Polymer 2019, 181, 121769.H. Ziyadi, M. Baghali, M. Bagherianfar, F. Mehrali, R. Faridi‐Majidi, Adv. Compos. Hybrid Mater. 2021, 4, 768.Z. Zhang, Y. Zhao, Z. Li, L. Zhang, Z. Liu, Z. Long, Y. Li, Y. Liu, R. Fan, K. Sun, Z. Zhang, Adv. Compos. Hybrid Mater. 2022, 5, 513.M. Ren, Y. Zhou, Y. Wang, G. Zheng, K. Dai, C. Liu, C. Shen, Chem. Eng. J. 2019, 360, 762.Y. X. Song, W. M. Xu, M. Z. Rong, M. Q. Zhang, Adv. Compos. Hybrid Mater. 2022, 5, 513.R. Liu, J. G. Kim, P. Dhakal, W. Li, J. Ma, A. Hou, C. Merkel, J. Qiu, M. Zoran, S. Wang, Adv. Compos. Hybrid Mater. 2023, 6, 14.S. Sharafkhani, M. Kokabi, Adv. Compos. Hybrid Mater. 2022, 5, 3081.M. Liu, H. Wu, Y. Wu, P. Xie, R. A. Pashameah, H. M. Abo‐Dief, S. M. EI‐Bahy, Y. Wei, G. Li, W. Li, G. Liang, C. Liu, K. Sun, R. Fan, Adv. Compos. Hybrid Mater. 2022, 5, 2021.P. Wang, T, S., H, M. A.‐D., J. Song, A. K. Alanazi, B. Fan, M. Huang, Z. Lin, A. A. Altalhi, S. Gao, L. Yang, J. Liu, S. Feng, T. Cao, Adv. Compos. Hybrid Mater. 2022, 5, 1100.Z. Yan, S. Wang, J. Bi, Q. He, H. Song, I. H. E. Azab, S. M. EI‐Bahy, A. Y. Elnaggar, M. Huang, M. H. H. Mahmoud, J. Wang, Q. Shao, Adv. Compos. Hybrid Mater. 2019, 5, 2116.L. Song, J. Chen, B. B. Xu, Y. Huang, ACS Nano 2021, 15, 12.B. B. Xu, Q. Liu, Z. Suo, R. C. Hayward, Adv. Funct. Mater. 2016, 26, 3218.H. Wei, Z. Wang, H. Zhang, Y. Huang, Z. Wang, Y. Zhou, B. B. Xu, S. Halila, J. Chen, Chem. Mater. 2021, 33, 17.X. Dai, Y. Du, Y. Wang, Y. Liu, N. Xu, Y. Li, D. Shan, B. B. Xu, J. Kong, ACS Appl. Polym. Mater. 2020, 2, 3.Z. Wang, H. Zhou, D. Liu, X. Chen, D. Wang, S. Dai, F. Chen, B. B. Xu, Adv. Funct. Mater. 2022, 32, 2201396.Y. Liu, A. Sun, S. Sridhar, Z. Li, Z. Qin, J. Liu, X. Chen, H. Lu, B. Z. Tang, B. B. Xu, ACS Appl. Mater. Interfaces 2021, 13, 30.Z. Li, Y. Liu, M. Lei, A. Sun, S. Sridhar, Y. Li, X. Liu, H. Lu, Y. Q. Fu, B. B. Xu, Soft Matter 2020, 16, 1636.H. Li, J. Chen, X. Chang, Y. Xu, G. Zhao, Y. Zhu, Y. Li, J. Mater. Chem. A 2021, 9, 1795.C. Lozano‐Pérez, J. V. Cauich‐Rodríguez, F. Avilés, Compos. Sci. Technol. 2016, 128, 25.Y. Wang, Y. Jia, Y. Zhou, Y. Wang, G. Zheng, K. Dai, C. Liu, C. Shen, J. Mater. Chem. C 2018, 6, 8160.X. Wang, X. Liu, D. W. Schubert, Nanomicro Lett. 2021, 13, 64.J. Lin, W. Wang, J. Cheng, Z. Cui, J. Si, Q. Wang, W. Chen, J. Appl. Polym. Sci. 2020, 137, 49252.Y. Li, B. Zhou, G. Zheng, X. Liu, T. Li, C. Yan, C. Cheng, K. Dai, C. Liu, C. Shen, Z. Guo, J. Mater. Chem. C 2018, 6, 2258.J. F. Guan, J. Zou, P. Y. Liu, Y. X. Jiang, G. J. Yu, Ecotoxicol. Environ. Saf. 2020, 201, 110872.H. Bi, Y. Li, S. Liu, P. Guo, Z. Wei, C. Lv, Sens. Actuators 2018, 171, 1132.G. Xu, B. Li, T. X. Cui, L. Ling, X. Luo, Sens. Actuators, B 2018, 188, 405.X.‐W. Zhang, Y. Pan, Q. Zheng, X.‐S. Yi, J. Polym. Sci. B 2000, 38, 2739.S. Zhao, D. Lou, G. Li, Y. Zheng, G. Zheng, K. Dai, C. Liu, Y. Jiang, C. Shen, Compos. Sci. Technol. 2018, 163, 18.S. H. Hong, S. Hong, M.‐H. Ryou, J. W. Choi, S. M. Kang, H. Lee, Adv. Mater. Interfaces 2016, 3, 1500857.J. Wang, H. Guo, X. Shi, Z. Yao, W. Qing, F. Liu, C. Y. Tang, J. Colloid Interface Sci. 2019, 535, 239.
Advanced Materials Interfaces – Wiley
Published: Apr 1, 2023
Keywords: dopamine modification; electrospun; fitted model; flexible sensor
You can share this free article with as many people as you like with the url below! We hope you enjoy this feature!
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.